期刊文献+

工作场所空气中硒化氢的原子荧光光谱测定法

Determination of hydrogen selenide in workplace air with atomic fluorescence
原文传递
导出
摘要 目的 建立工作场所空气中硒化氢的原子荧光光谱测定法.方法 以装有0.1 mol/L氢氧化钠溶液的多孔玻板吸收管吸收硒化氢,硝酸和高氯酸(9+1)消化处理,在5.0%盐酸介质中,以硼氢化钾为还原剂使其还原为硒化氢,原子荧光光谱法测定硒含量.结果 硒在0~150 μg/L范围内线性良好,相关系数为0.999 9,方法检出限为0.1 μg/L,低、中、高浓度硒溶液精密度分别为3.1%、7.4%和6.7%.采样效率为99%以上.结论 该方法精密度和灵敏度较高,可以满足工作场所空气中硒化氢的测定. Objective To determin hydrogen selenide in workplace air with atomic fluorescence.Method Hydrogen selenide were sampled with 0.1 mol/L sodium hydroxide solution in multi-hole absorbing tubes.The sampled absorbing solution were digested with (9 +1 ) nitric acid/percloric acid.The selenide in sample were reduced by potassium borohydride in 5.0% hydrochloride solution and determined with atomic fluorescence.Results There was a good linearity (r=0.999 9) over the concentration of 0~150 μg/L,The precision of low,middle and high concentration were 3.1%,7.4% and 6.7%,respectively.The sample collection rate can reach 99%.Conclusion The method was accurate and sensitive to detect hydrogen selenide in workplace air.
出处 《中华劳动卫生职业病杂志》 CAS CSCD 北大核心 2012年第2期144-145,共2页 Chinese Journal of Industrial Hygiene and Occupational Diseases
关键词 光谱法 原子荧光 硒化氢 空气 Atomic fluorescence spectrometry Hydrogen selenide Air, workplace
  • 相关文献

参考文献9

  • 1Manjusha R,Dash K,Karunasagar D.UV-photolysis assisted digestion of food samples for the determination of selenium by electrothermal atomic absorption spectrometry (ETAAS).Food Chemistry,2007,105:260-265. 被引量:1
  • 2李明远.微波消解-氢化物原子荧光光谱法测定食品中的微量元素硒[J].光谱实验室,2007,24(4):618-621. 被引量:19
  • 3Masson P,Orignac D,prunet T.Optimization of selenium determination in plant samples by hydride generation and axial view inductively coupled plasma atomic emission spectrometry.Analytica Chi mica Acta,2005,545:79-84. 被引量:1
  • 4Moskvin L.N,Bulatov A.V,Rudenko E.A,et al.Photometric determination of trace selenium in aqueous media.J Anal Chem,2006,61:25-27. 被引量:1
  • 5Zhang B.C,Xu H,Yu J.C.Determination of total gaseous selenium in atmosphere by honeycomb denuder/differential pulse cathodic stripping voltammetry.Talanta,2002,57:323-331. 被引量:1
  • 6Seki R,Oono S,Usui T,Neutron activation analysis of selenium in human toe-nail[J].Genken Shisetsu Riyo Kyodo Kenkyu Seika Hokokusho,2004,33:101-105. 被引量:1
  • 7Strausz K.I,Purdham J.T,Strausz O.P.X-ray fluorescence spectrometric determination of selenium in biological materials.Analytical Chemistry,1975,47:2032-2034. 被引量:1
  • 8查河霞,于平胜,缪吉霞.氢化物发生原子荧光法测定茶叶中硒[J].中国卫生检验杂志,2007,17(4):639-640. 被引量:10
  • 9贺宝芝,董夏,刘永刚.阳极溶出伏安法测定车间空气中硒化氢[J].中国卫生检验杂志,1994,4(6):333-335. 被引量:1

二级参考文献6

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部