介绍调制温度式差示扫描量热仪(MDSC)技术的工作原理,并通过实例比较差示扫描量热仪(DSC)与调制温度式差示扫描量热仪(MDSC)两种测试技术的不同及MDSC的优点。
The principle of modulated differential scanning(MDSC) was introduced firstly,and then the differences between general differential scanning calorinetry(DSC) and MDSC were analyzed by two examples.The results showed that MDSC had more advantages than general DSC.
出处
《实验室科学》
2011年第6期97-99,106,共4页
Laboratory Science
基金
国家人才培养模式创新实验区建设项目(2008)
苏州大学化学化工与材料学教学改革研究项目资助(2009)
关键词
调制温度式差示扫描量热仪
热分析法
差示扫描量热仪
modulated differential scanning calorinetry(MDSC)
thermal analysis
differential scanning calorinetry(DSC)