期刊文献+

空气阀门性能试验测试装置对比研究 被引量:5

Comparison of Air Valve Performance Test Equipment
下载PDF
导出
摘要 对比了空气阀门性能试验国内标准JB/T 7228-94、欧联标准BS EN1751:1999及美国标准AMCA 500-D-2007中对测试阀门上下游管道长度及压力测点位置的不同要求,选取阀门模型按照JB/T与BS EN标准分别进行了流阻及流量特性试验,并对阀门上下游管道内流场进行测试,结果表明试验阀门上游管道可以缩短至欧联标准要求。 The national standards of air performance test valve JB / T 7228-94,EU standard BS EN1751: 1999 and American Standard AMCA 500-D-2007 to test the valve in the pipe length upstream and downstream of the different requirements were compared.According to JB/T respectively and the BS EN standards,selecting the valve model do the flow resistance and flow ratio tests,and flow field test in the pipeline of test valves upstream and downstream.Results show that the upstream pipeline valve test can be shortened to international standards.
出处 《流体机械》 CSCD 北大核心 2012年第1期6-9,共4页 Fluid Machinery
关键词 空气阀门 测试装置 对比 air valve test equipment comparison
  • 相关文献

参考文献4

  • 1JB/T 7228-94,风量调节阀[S]. 被引量:3
  • 2BS EN1751:1999, Ventilation for buildings-Air termi- nal devices-Aerodynamic testing of dampers and valves [S]. 被引量:1
  • 3ANSI/AMCA Standard 500-D-07, Laboratory Methods of Testing Dampers for Rating[ S]. 被引量:1
  • 4GB/T1236-2000.工业通风机用标准化风道进行性能试验[S].[S].国家质量技术监督局发布,2000.108-110. 被引量:25

共引文献25

同被引文献35

引证文献5

二级引证文献22