期刊文献+

基于无线传输的数字X射线成像与处理系统的研究与框架构建 被引量:2

Research and framework construction for a digital X ray imaging and processing system based on wireless transmission
下载PDF
导出
摘要 目的:研究探讨及构建一种体积小、重量轻、易于携带且方便使用的低剂量数字X射线成像仪。方法:采用二极管线性阵列(LDA)探测器和成像系统(CMOS互补金属氧化物半导体/晶体管)传感器相结合的组合方式进行构建。结果:可一步完成X射线光电转换、数字采集的过程,实现直接数字化成像。将数字X射线成像仪所获取的数字成像信号进行无线传输,通过无线传输,将数据传输到服务器上以便医师进行分析。结论:构架出一个对X射线成像设备进行数字成像并进行无线数据传输的系统装置,并具有便携、易用、军民两用的特点。 Objective: To research and construct a digital X ray imaging apparatus with small volume, light weight, easy portability and low dose. Methods: The digital X ray imaging apparatus was constructed by using the linear array detector and imaging system sensor in combination. Results: This mode can be further used to complete X ray photoelectric conversion, digital acquisition and realized direct digital imaging. This digital X ray imaging apparatus acquired digital imaging signal, transmitted the data to the server through wireless transmission, then the data were analyzed conveniently by physicians. Conclusion: This device of digital imaging and wireless transmission has been constructed for the X ray advantages of convenience, portability and dual-use characteristics.
出处 《中国医学装备》 2012年第1期19-22,共4页 China Medical Equipment
关键词 数字X线成像系统 无线传输 研究框架 Digital X ray imaging system Wireless transmission Frame construction
  • 相关文献

参考文献10

二级参考文献48

共引文献91

同被引文献17

  • 1Mohammad Mehdi NASSERI.Monte-Carlo simulation for determining SNR and DQE of linear array plastic scintillating fiber[J].Nuclear Science and Techniques,2004,15(5):304-307. 被引量:3
  • 2白玫,刘旭,彭明辰.数字X射线成像设备DQE的测试[J].医疗设备信息,2007,22(4):1-4. 被引量:13
  • 3IEC 62220-1.Medical electrical equipment- Characteristics of digital X-ray imaging devices-Part 1.Determination of the detective quantum efficiency[S]. IEC, 2003-10-01. 被引量:1
  • 4国家食品药品监督管理局.YYT0741-2009数字化医用X射线摄影系统专用技术标准[S].国家食品药品监督管理局,2009-11-15. 被引量:1
  • 5Samei E,Flynn MJ,Reimann DA.A method for measuring the presampled MTF of digital radiographic systems using an edge test device[J].Med Phys, 1998,25(1): 102-113. 被引量:1
  • 6Awai K,Komi M,Hori S.Selenium-based digital radiography versus high-resolution storage phosphor radiography in the detection of solitary pulmonary nodules without calcification:receiver operating characteristic curve analysis[J].AJR Am J Roentgenol,2001, 177(5): 1141-1144. 被引量:1
  • 7Ludwig K, Link TM, Fiebich M,et al. Selenium- based digital radiography in the detection of bone lesions: preliminary experience with experimentally created defects[J]. Radiology, 2000,216( 1 ): 220-224. 被引量:1
  • 8Denny L,Kelly P,Jeffrey G,et al. Direet- conversion x-ray detectors using amorphous selenium[J]. Journal of X-ray Science and Technology, 2002, 10(1 ): 17-36. 被引量:1
  • 9Oda K,Tsuzaka M.Evaluation of moire artifacts with stationary anti-scatter grids in amorphous selenium-based flat panel X-ray detector system[J].Medical Imaging SPIE, 2007,6510(2) : 401-405. 被引量:1
  • 10Samei E,Nicole TR, James TD,et al. Intercom- parison of methods for image quality characterization I modulation transfer function[J]. Medical Physics,2006,33(5): 1454-65. 被引量:1

引证文献2