钢筋混凝土无洞叠合墙体非线性有限元分析 被引量:6

Nonlinear finite element analysis on composite reinforced concrete shear walls without opening
下载PDF
导出
摘要 在试验研究的基础上,运用有限元分析程序ANSYS对钢筋混凝土无洞叠合墙体进行非线性分析。通过建立合理的力学模型,模拟分析了叠合墙体的裂缝开展与分布、承载能力、破坏模式等方面的特点和规律,并与试验结果进行对比验证。有限元值与试验值吻合较好,说明本研究在进行有限元分析时所选择的计算模型、材料本构关系、破坏准则等较为合理的,可以应用于叠合剪力墙的进一步分析研究,弥补试验研究的局限性。剪式支架能使钢筋混凝土叠合剪力墙的预制部分与现浇混凝土形成整体,共同工作,承受外部荷载。 Based upon the experimental studies,nonlinear finite element analysis on composite reinforced concrete shear wall without opening by using finite element software ANSYS was comprehensively studied.Based on the reasonable mechanics models and methodologies,the seismic behavior was researched for the wall structure on the horizontal loading test.The crack expansion,failure mode were discussed.The prefabricated parts and the cast-in-situ concrete parts of the composite reinforced concrete shear walls could work together in coordination very well under loading.
出处 《混凝土》 CAS CSCD 北大核心 2012年第1期18-20,23,共4页 Concrete
基金 江苏省自然科学基金(BK2008377) 江苏省建设厅项目(JS2009ZB04) 南京工业大学青年教师学术基金(39713015) 江苏省绿色建筑工程技术研究中心项目(2009)
关键词 无洞叠合剪力墙 有限元分析 抗震性能 节能 composite shear wall without opening finite element analysis seismic behavior energy saving
  • 相关文献

参考文献6

  • 1王滋军,刘伟庆,叶燕华,等.一种适合工业化生产的节能建筑结构体系:中国,ZL200920044967.4[P].2010-02-24. 被引量:5
  • 2卢吉松.节能环保型钢筋混凝土叠合结构体系墙体抗震性能试验研究[D].南京:南京工业大学,2010. 被引量:5
  • 3JGJ101-96.建筑抗震试验方法规程[S].[S].,.. 被引量:199
  • 4G1350011-2010,建筑抗震设计规范[S]. 被引量:3
  • 5JGJ3-2002.高层建筑混凝土结构技术规程[S].[S].,.. 被引量:945
  • 6GB50010--2010混凝土结构设计规范[S]. 被引量:1374