摘要
以系统的纯迟延作为先验知识,通过分离与重构系统误差的随机性和确定性分量,分别计算热工控制系统随机性和确定性性能指标,分析了多类扰动下的系统综合性能评价问题。并利用某电厂实际的正常运行数据对研究的结论进行了验证。结果表明,所提出的评价方法客观地反映了控制系统的实际运行状态。
In this paper,the system pure delay as a priori knowledge,through the separation and reconstruction of the random and deterministic system error component,we calculated the thermal control system of random and deterministic performance,analysis of many types of system disturbance comprehensive performance evaluation.And the actual use of the normal operation of a power plant on the findings of the study data were verified.The results show that the proposed evaluation method to objectively reflect the actual control system running.
出处
《电力科学与工程》
2011年第12期59-63,72,共6页
Electric Power Science and Engineering
关键词
最小方差
性能评价
ARMA模型
随机性能
确定性能
主汽压力
minimum variance
performance evaluation
ARMA models
random performance
determine performance
main steam pressure