期刊文献+

Sensitive Voltammetric Determination of Captopril Using a Carbon Paste Electrode Modified with Nano-TiO_2/Ferrocene Carboxylic Acid 被引量:6

Sensitive Voltammetric Determination of Captopril Using a Carbon Paste Electrode Modified with Nano-TiO_2/Ferrocene Carboxylic Acid
下载PDF
导出
摘要 A carbon paste electrode (CPE) modified with ferrocene carboxylic acid (FcCA) and TiO2 nanoparticles was constructed by incorporating TiO2 nanoparticles and ferrocene carboxylic acid into the carbon paste matrix. The electrochemical behavior of captopril (CAP) at the surface of the modified electrode was investigated using electroanalytical methods. The modified electrode showed excellent electrocatalytic activity for the oxidation of CAP in aqueous solutions at physiological pH values. Cyclic voltammetric curves showed that the oxidation of CAP at the surface of the modified electrode reduced its overpotential by more than 290 mV. The modified electrode was used for detecting captopril using cyclic voltammetry and square wave voltammetry techniques. A calibration curve in the range of 0.03 to 2400 μmol/L was obtained that had a detection limit of 0.0096 μmol/L (3?) under the optimized conditions. The modified electrode was successfully used for the determination of captopril in pharmaceutical and biological samples. A carbon paste electrode (CPE) modified with ferrocene carboxylic acid (FcCA) and TiO2 nanoparticles was constructed by incorporating TiO2 nanoparticles and ferrocene carboxylic acid into the carbon paste matrix. The electrochemical behavior of captopril (CAP) at the surface of the modified electrode was investigated using electroanalytical methods. The modified electrode showed excellent electrocatalytic activity for the oxidation of CAP in aqueous solutions at physiological pH values. Cyclic voltammetric curves showed that the oxidation of CAP at the surface of the modified electrode reduced its overpotential by more than 290 mV. The modified electrode was used for detecting captopril using cyclic voltammetry and square wave voltammetry techniques. A calibration curve in the range of 0.03 to 2400 μmol/L was obtained that had a detection limit of 0.0096 μmol/L (3?) under the optimized conditions. The modified electrode was successfully used for the determination of captopril in pharmaceutical and biological samples.
出处 《催化学报》 SCIE EI CAS CSCD 北大核心 2011年第11期1685-1692,共8页
关键词 ELECTROCATALYSIS modified electrode NANO-TIO2 ferrocene carboxylic acid captopril cyclic voltammetry electrocatalysis modified electrode nano-TiO2 ferrocene carboxylic acid captopril cyclic voltammetry
  • 相关文献

参考文献2

二级参考文献7

  • 1[6]T.H. Zhang and Y.G. Wu, Nuclear Technology 18 (1995) 577. 被引量:1
  • 2[7]T.H. Zhang and Y.G. Wu, J. Beijing Normal University (Natural Science) 30 (1994) 479. 被引量:1
  • 3[1]S.S. L au, J.S.-Y. Feng, J.O. Olowolafe and M.-A. Nicolet, Mayer, Thin Solid Film 25 (1975) 415. 被引量:1
  • 4[2]S. Mantl, Material Science Report 8 (1992) 1. 被引量:1
  • 5[3]T.H. Zhang, J. Chen, G.R. Sun, Y.G. Wu, Y. Luo and X.J. Ding, Surface and Coating Technology 66(1994) 355. 被引量:1
  • 6[4]T.H. Zhang, Y.G. Wu, H. Liang, W.D. Qian and Y. Luo, J. Beijing Normal University (Natural Science)30 (1994) 357. 被引量:1
  • 7[5]T.H. Zhang and Y.G. Wu, Chinese Journal of Semiconductors 21(6) (2000) 542. 被引量:1