期刊文献+

超临界直流锅炉水冷壁动态特性试验研究(Ⅰ) 被引量:2

An Experimental Research into Dynamic Characteristic of Suppercritical Once-Through Boiler Water Wall
下载PDF
导出
摘要 本文介绍超临界直流锅炉水冷壁动态特性试验结果。在出口压力、热负荷、进口质量流速和进口温度参数扰动下,确定水冷壁参数动态变化规律和响应曲线,并进行了理论分析。试验的目的在于为确定输入和输出参数间的传递函数提供可靠的依据。 This paper introduces dynamic characteristic test results of suppercritical once-through boiler water walls. From experimental readings, the dynamic changing regularity of water wall parameters and the response curve are confirmed under the disturbance of outlet pressure, heat load, inlet mass flow speed and inlet temperature. Sone theoretical analyses are given. The test purpose is to provide a reliable basis for obtaining transmit functions between inpnt and output parameters.
出处 《上海电力学院学报》 CAS 1995年第3期9-17,共9页 Journal of Shanghai University of Electric Power
基金 电力部电力科技发展基金
关键词 螺旋管圈 直流锅炉 超临界压力 动态特性 响应曲线 spiral circle tube once-through boiler supercritical pressure dynamic characteristic response curve