摘要
介绍2TGD型工频感应电炉冷却用水技术要求、循环冷却水系统设计、主要设施设置、工程设计参数、封闭式冷却技术选择和封闭式冷却器设备引进情况,以及工程设计体会。
Here is introduced the tech to use water for cooling a 2TGD type two - frequence electric induction furnace, the method to design a circulating water system, the way to collocate all main installation, and the principles to choose the engineering - designing parameters and ciosed cooling tech necessary, and reported the closed coolers imported as well as the experiences related.
出处
《有色设备》
1998年第4期22-24,48,共4页
Nonferrous Metallurgical Equipment
关键词
封闭式冷却水系统
工程设计
设备引进
Closed cooling water system
Engineering Design
Equipment import