期刊文献+

直排式真空预压法加固高黏性超软吹填土室内模型试验研究 被引量:10

Laboratory model test of reinforcing heavy clay recently reclaimed soil by straight-line vacuum preloading
下载PDF
导出
摘要 大连某港区高黏性超软吹填土采用常规真空预压和堆载预压处理效果不佳,为寻求解决方案,采用直排式真空预压法进行了室内模型试验,通过不同排水体、不同排水间距的室内对比试验和综合分析,得出采用直排式真空预压法加固高黏性超软吹填土时排水体间距起主导作用的结论。 It had poor effect to reinforce heavy clay recently reclaimed soil with routine vacuum preloading and surcharge preloading in Dalian port.The straight-line vacuum preloading method was adopted to carry on the laboratory model test for finding a solution.The result was that the drain spacing played a leading role to reinforce heavy clay recently reclaimed soil by straight-line vacuum preloading,through indoor comparison test and comprehensive analysis on different drainage materials and different drain spacings.
出处 《水运工程》 北大核心 2011年第10期125-131,共7页 Port & Waterway Engineering
关键词 模型箱试验 吹填软土 直排式真空预压 固结 加固效果 test by chambers in laboratory soft dredger fill straight-line vacuum preloading consolidation reinforcing effect
  • 相关文献

参考文献5

二级参考文献7

共引文献131

同被引文献50

引证文献10

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部