期刊文献+

ActiveX控件型VAS量规的设计和信度评价 被引量:14

Design and reliability evaluation of visual analogue scale based on ActiveX control
下载PDF
导出
摘要 视觉模拟评分法是被广泛应用的主观指标量规。标准视觉模拟评分法量规以往呈现多种型态,而且各型存在不同的局限性。该研究旨在以临床知情同意书的易读性评价为实验模型,探索ActiveX控件型视觉模拟评分法量规的设计和信度分析,发现采用Microsoft Slider control,version 6.0控件模拟视觉模拟评分法量规度量主观指标,不仅克服了以往标准视觉模拟评分法量规的局限性,而且是内在信度较高的主观感受量规。 Visual analogue scales(VAS) is a widely used scale for measuring subjective indexes.Absolute VAS used to present various modes,all of which have their own limitations.The study aimed to design VAS based on ActiveX control and test its reliability by evaluating the readability of clinical informed consent and has found that VAS based on simulation of Microsoft Slider control not only can overcome the shortcomings of different modes of absolute VAS but also is a scale for measuring subjective perception with relatively high internal reliability.
出处 《中国医学教育技术》 2011年第5期532-534,共3页 China Medical Education Technology
基金 陕西省科学技术研究发展计划项目:口腔颌面疾病研究(3)(2005K14-G8(3))课题研究成果之一
关键词 主观评价 知情同意书 视觉模拟评分法 ACTIVEX控件 subjective assessment informed consent visual analogue scale ActiveX control
  • 相关文献

参考文献10

  • 1Wikimedia Foundation. Visual analogue scale-Wikipedia, the free encyclopedia. 2011 [ EB/OL]. http://en, wikipedia. org/wiki/Visual_analogue_scale. 被引量:1
  • 2Wewers M E, Lowe N K. A critical review of visual analogue scales in the measurement of clinical phenomena[ J ]. Res In Nursing & Health, 1990,13 (4) :227-36. 被引量:1
  • 3McCormack H M, Home D J, Sheather S. Clinical applications of visual analogue scales: a critical review [ J ]. Psychological Medicine, 1988,18 (4) : 1007-1019. 被引量:1
  • 4Schiffer R B, Rao S M, Fogel B S. Neuropsychiatry [ M ]. 2nd Edition ed. USA: Philadelphia: Lippincott Williams & Wilkins, 2003:800-801. 被引量:1
  • 5Aitken R C. Measurement of feelings using visual analogue scales [ J ]. Proc R Soc Med, 1969,62 (10) :989-993. 被引量:1
  • 6Paul-Dauphin A. Bias and precision in visual analogue scales: a randomized controlled trial [ J ]. American Journal Of Epidemiology, 1999,150 (10) : 1117-1127. 被引量:1
  • 7Pointer J S. A novel visual analogue scale (VAS)device: an instrument based on the VAS de-signed to quantify the subjective visual experience [ J ]. Ophthalmic Physiol Opt, 2004,24(3) :181-185. 被引量:1
  • 8Jamison R N, et al. Comparative study of electronic vs. paper VAS ratings: a randomized, crossover trial using healthy volunteers [ J ]. Pain, 2002,99 (1-2) : 341-347. 被引量:1
  • 9Frederik F, Reips U. VAS Generator. 2011 [ EB/OL ]. http:// vasgenerator, net/. 被引量:1
  • 10Lundqvist C. A vertical VAS is a valid instrument for monitoring headache pain intensity [ J ]. Cephalalgia,2009, 29(10) : 1034-1041. 被引量:1

同被引文献121

引证文献14

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部