期刊文献+

列车空调军团菌污染状况及人群感染水平的实验研究 被引量:4

An experimental study of Legionella contamination in train air- conditioning
下载PDF
导出
摘要 目的了解列车空调车I刹菌污染状况及相关人员军冈菌感染情况。方法从合肥车辆段徐州区间的客车服务人员中,抽取列车乘务人员和站台售货人员各400名,组成实验组(乘务人员组)和对照组(站台组),做血清军团菌抗体检测;采集的风管积尘样和空调冷凝水样按规范进行军团菌分离培养和鉴定,并以PER方法确证。结果乘务人员组军网菌感染阳性率为53.65%,与站台组阳性率(17.3%)差异有统计学意义(P〈0.01),人群感染军团菌菌型主要为Lp6;列车空调军团菌污染率为19.39%,积尘中车团菌阳性率与冷凝水中阳性率差异有统计学意义(P〈0.01),检出主要菌划为Lp1。结论列车空调风管积尘的采集更具有军团菌流行病学的代表意义,健康人群中可能存在军团菌的机会件感染。 Objective We want to understand the case of Legionella pollution in the train and related personnel Legionella infection. Method Taking the train crew amt station sales staff of 400 from Xuzhou, Hefei depot serviee staff, composed of test and control group, ingenious and to be detected with serum antibody of Legionella. Dust samples and water samples collected from train air- conditioning condensation were treated with acid -heating, then vaccinated in GVPC in isolating and identifying finally , being compared with the site, there are significant differences (P 〈0.01 ). The main Legionella type people infected was Lp6. The contamination rate of the train air - conditioning was 19.39%, Dust in Legionella -positive rate was far higher than the positive rate of water condensation (P 〈 0. 01 ), and the main type deteeted in experiment was Lpl. Conclusion Colleeting duet dust is more representative of epideminlogical significance. Legionella opportunistic infections may exist in healthy population.
出处 《徐州医学院学报》 CAS 2011年第9期584-586,共3页 Acta Academiae Medicinae Xuzhou
基金 上海铁路局科技推广项目(2009091)
关键词 列车空调 军团菌污染 人群感染 train air- eondilioning Legionella contamination human infection
  • 相关文献

参考文献8

二级参考文献10

共引文献40

同被引文献38

  • 1姜红梅,邵祝军,李建铭,邹梅,张淑云,孙亚慧,徐东群.大连市集中空调场所军团菌污染及人群健康状况影响调查[J].卫生研究,2009,38(1):76-77. 被引量:19
  • 2旅客列车卫生及监测技术规定(TB/T1932-2009)[S].铁道部,2009. 被引量:4
  • 3WS394-2012,公共场所集中空调通风系统卫生规范[s]. 被引量:11
  • 4杨克敌.环境卫生学[M].第7版,北京:人民卫生出版社,2012:195. 被引量:14
  • 5World Health Organization. Disease outbreak news: Legion- naires' disease-Portugal [ Z ]. WHO, 2014, 11. http://www. who. int/csr/don/13 - november - 2014 - legionellosis/en/. 被引量:1
  • 6Erik VE, Douglas GA, Matthias E, et al. The strengthening the reporting of observational studies in epidemiology ( STROBE ) statement: guidelines for reporting observational studies[ J]. J of Clin Epidem, 2008,61:344-349. 被引量:1
  • 7张莉君,东春阳,顾青.等.公共场所军团菌污染及人群感染状况调查[A].中国疾病预防控制中心环境与健康相关产品安全所、中华预防医学会环境卫生分会,2011年全国环境卫生学术年会论文集[C].中国疾病预防控制中心环境与健康相关产品安全所、中华预防医学会环境卫生分会2011,4. 被引量:1
  • 8Katarzyna P, Daniel R, Hanna SM. The influence of contamina- tion of a hospital hot-water system with legionella pneumophila on serum antibody production by staff members [ J ]. Indoor Built Environ, 2006, 15(1): 105-109. 被引量:1
  • 9David C, Jamie B, Emmanuel B. Water safety in buildings[ J]. WHO, 2011. 被引量:1
  • 10国家质检总局.出入境口岸军团菌检验标准[S](SN/T2351-2009).北京:中国标准出版社,2009. 被引量:1