期刊文献+

射频信号上的快速弹性成像位移估计方法 被引量:2

Radio frequency signal based fast displacement estimation method for elastography
下载PDF
导出
摘要 目的提高射频(RF)信号上的超声弹性成像位移估计速度。方法利用弹性成像位移估计窗口的重叠特征,设计快速的互相关位移估计方法。通过仿真内含一硬包容物的组织(60 mm×50 mm),包容物直径为20 mm,且均匀分布在中轴线上,其弹性模量为背景10倍的体模弹性成像实验验证新方法的效果。结果在体模弹性成像实验中新方法的位移估计平均时间[(74.13±4.30)s]比传统方法[(166.52±63.32)s]低。结论使用新方法不仅能产生与传统方法一致的位移和弹性图像,还具有较低的时间复杂度优势。 Objective To improve the velocity of radio frequency(RF) signal based displacement estimation method for ultrasonic elastograph.Methods By analyzing the property of overlap between the displacement estimator windows,a new efficient method of displacement estimate method has been designed.A 60 mm×50 mm tissue model was simulated with one round hard inclusions of 20 mm diameter uniformly distributed along the tissue central axial line,and its elasticity modulus were 10 times of the background.Results In the simulated experiment,the average displacement estimate time of the conventional method and the new method were(166.52±63.32) seconds and(74.13±4.30) seconds,respectively.The latter was obviously lower.Conclusion The experiment shows that the new method could generate same displacement data and same ultrasound elastography as the convetional method and need less runtimes.
作者 何兴无
出处 《重庆医学》 CAS CSCD 北大核心 2011年第27期2711-2713,共3页 Chongqing medicine
关键词 超声检查 位移估计 互相关 弹性成像技术 ultrasonography displacement estimation cross-correlation elastiloty imaging techniques
  • 相关文献

参考文献15

  • 1Ophir J, Cespedes I, Ponnekanti H, et al. Elastography: a quantitative method for imaging the elasticity of biological tissue[J]. Ultrasonic Imaging, 1991,13(3) : 111-134. 被引量:1
  • 2王彬,李发琪.声辐射力弹性成像:弹性成像的新发展[J].中国医学影像技术,2011,27(4):852-856. 被引量:51
  • 3Bilgen M,Insana MF. Deformation models and correlation analysis in elastography[J]. J Acoust Soc Am, 1996,99 (5) : 3212-3224. 被引量:1
  • 4Cespedes I, Ophir J, Ponnekanti H, et al. Elasticity ima- ging using ultrasound with application to muscle and breast in vivo [J]. Ultrasonic Imaging,1993,5(2) :73-88. 被引量:1
  • 5Srinivasan S, Ophir J. A Zero-crossing Strain Estimator for Elastography[J]. Ultrasound Med Biol, 2003,29 (2) 227-238. 被引量:1
  • 6Eskandari H, Salcudean SE, Rohling R. Tissue strain ima- ging using a wavelet transform-based peak search algo- rithm[J]. IEEE Trans Ultrason Ferroelectr Freq Control,2007,54(6):1118-1130. 被引量:1
  • 7Lindop JE,Treece GE,Gee A,et al. Phase-based ultrason- ic deformation estimation [J].IEEE Trans Ultrason Fer roelectr Freq Control,2008,55(1) :94-111. 被引量:1
  • 8Pesavento A,Perrey C,Krueger M, et al. A time-efficient and accurate strain fstimation concept for ultrasonic elas tography using iterative phase zero estimation[J]. IEEE Trans Ultrason Ferroelectr Freq Control, 1999, 46 (5): 1057- 1067. 被引量:1
  • 9Konofagou EE, D' hooge J, Ophir J. Myocardial elastogra- phy--a feasibility study in vivo[J]. Ultrasound Med Bi- ol, 2002,28 (4) : 475-82. 被引量:1
  • 10Jensen JA, Munk P. Computer phantoms for simulating ultrasound B-mode and CFM images[J]. Acoust Imaging Symp ,1997 ( 23 ) :75-80. 被引量:1

二级参考文献31

  • 1Mateke C, Konofagou EE. Single-element focused ultrasound transducer method for harmonic motion imaging. Ultrason Ima-ging, 2006,28(3):144- 158. 被引量:1
  • 2Vappou J, Maleke C, Konot'agou EE. Quantitative viscoelastic parameters measured by harmonic motion imaging. Phys Med Bi- ol, 2009,54(11) :3579-3594. 被引量:1
  • 3Konofagou EE, Hynynen K. Localized harmonic motion imaging: theory, simulations and experiments. Ultrasound in Med ~ Biol, 2003,29(10) : 1405-1413. 被引量:1
  • 4Urban MW, Chen S, Greenleaf J. Harmonic motion detection in a vibrating scattering medium. IEEE Trans Ultrason Ferroelectr Freq Control, 2008,55(9) : 1956-1974. 被引量:1
  • 5Shan B, Kogit ML, Pelegri AA. Dynamic simulation of viscoelas- tic soft tissues in harmonic motion imaging application. J Bio mech, 2008,41(14) :3031-3037. 被引量:1
  • 6Shan B, Pelegri AA, Maleke C, et al. A mechanical model to compute elastic modulus of tissues for harmonic motion imaging. J Biomech, 2008,41(10):2150 2158. 被引量:1
  • 7Heikkil~i J, Hynynen K. Simulations of lesion detection using a combined phased array LHMI-technique. Ultrasonics, 2008, 48 (6-7) : 568-573. 被引量:1
  • 8Nightingale KR, Nightingale RW, Palmeri ML, et al. A finite el- ement model of remote palpation of breast lesions using radiation force: factors affecting tissue displacement. Ultrason Imaging, 2000,22( 1 ) : 35-54. 被引量:1
  • 9Nightingale KR. On the feasibility of remote palpation using a- coustic radiation force. J Acoust Soc Am, 2001,110(1) :625-634. 被引量:1
  • 10Nightingale K, Trahey G. Acoustic radiation force impulse ima ging: in vivo demonstration of clinical feasibility. Ultrasound Med Biol, 2002,28(2) :227 235. 被引量:1

共引文献50

同被引文献21

  • 1宋凝,陈立仁.聚苯乙烯包夹硅基高效液相色谱固定相的研究[J].色谱,1994,12(6):398-400. 被引量:10
  • 2Cantisani V,D'Andrea V,Biancari F, et al. Prospective evaluation of multiparametric ultrasound and quantitative elastosonography in the differential diagnosis of benign and malignant thyroid nodules: preliminary experience[J]. Eur J Radiol, 2012,81(10): 2678-2683. 被引量:1
  • 3Ning CP, Jiang SQ, Zhang T, et al. The value of strain ratio in differential diagnosis of thyroid solid nodules [J]. Eur J Radiol, 2012, 81(2): 286-291. 被引量:1
  • 4Rago T, Santini F, Scutari M, et al. Elastography: new developments in ultrasound for predicting malignancy in thyroid nodules [J]. J Clin Endocrinol Metab, 2007,92(8): 2917-2922. 被引量:1
  • 5Cantisani V,D'Andrea V,Biancri F, et al. Prospective evaluation of multiparametric ultrsoluld and quantitative elastosonography in the differential diagnosis of benign and malignant thyroid nodules: preliminary experience[J]. Eur J Radiol, 2012, 81(10): 2678-2683. 被引量:1
  • 6Ning CP, Jiang SQ, zhang T, et al. The value of strain ratio in differential diagnosis of thyroid solid nodules[J]. Eur J Radiol, 2012, 81(2): 286-291. 被引量:1
  • 7Xing P, Wu L, Zhang C, et al. Differentiation of benign from malignant thyroid lesions: calculation of the strain ratio on thyroid sonoelastography[J]. J Ultrasound Med, 2011,30(5): 663-669. 被引量:1
  • 8Kagoya R, Monobe H, Tojima H, et al. Utility of elastography for differential diagnosis of benign and malignant thyroid nodules[J]. Otolargol Head Neck Surg, 2010, 143(2): 230-234. 被引量:1
  • 9谢渝春,刘会洲,陈家镛.手性HPLC法测定布洛芬立体选择性酯化的转化率和对映体过量[J].色谱,1998,16(1):56-58. 被引量:9
  • 10杨瑞琴,蒋生祥,刘霞,陈立仁.苯乙烯和马来酸酐包夹硅胶弱阳离子色谱柱的制备及其应用[J].色谱,1998,16(4):281-284. 被引量:7