摘要
火焰原子吸收光谱法测定废水中的重金属含量,具有省时、省力、测定准确度高等特点,但在测定过程中受到外部因素的影响,往往会使测定的结果发生偏离,所以应对外部影响因素采取适当的质量控制措施,以获得准确的测定结果。
FAAS has advantages of saving time and labor,and high accuracy for determining heavy metals in waste water,but in the process the external factors often made determination deviate the accurate result.So some quality control measures in allusion to the influence of external factors were took to obtain accurate result.
出处
《光谱实验室》
CAS
CSCD
北大核心
2011年第5期2498-2500,共3页
Chinese Journal of Spectroscopy Laboratory
关键词
火焰原子吸收光谱法
重金属
质量控制
Flame Atomic Absorption Spectrometry
Heavy Metal
Quality Control