期刊文献+

惯性约束聚变反应速率测量 被引量:7

Measurement of inertial confinement fusion reaction rate
下载PDF
导出
摘要 聚变反应速率是表征惯性约束聚变热核反应的重要参数,为测量聚变反应速率,研制了一套由闪烁体及鼻锥部分、光学系统和条纹相机组成的测量系统。在神光Ⅲ原型装置上利用新研制的聚变反应速率测量系统进行了聚变反应速率测量。在DT中子产额约为1010条件下,首次获得了聚变反应速率随时间的变化过程。对影响聚变反应速率测量的相关因素进行详细分析后表明,系统的时间分辨力优于30ps。 Fusion reaction rate is an important parameter for measuring compression during the bnplosion in incrHal confine ment fusion experiment. We have developed a system for fusion reaction history measurement with high temporal resolution. The system is composed of plastic scintillator and nose cone, optical system and streak camera. We have applied this system on the SGⅢ prototype for fusion reaction rate measuring, For the first time, fusion reaction rate history have been measured for deutcrium tritium filled targets with netrons yields about 10^10. We have anatomized possible influence factor during fusion reaction rate meas uring. It indicates that the instrument measures fusion reaction bang time at temporal resolutions as low as 30 ps.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2011年第8期2197-2200,共4页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(10805041)
关键词 惯性约束聚变 聚变反应速率 热核反应 条纹相机 中子 inertial confinement fusion fusion reaction rate thermonuclear fusion streak camera nelron
  • 相关文献

参考文献8

  • 1Lindl J D, Amendt P, Berger R L, et al. The physics basis for ignition using indirect drive targets on the National Ignition Facility[J].Phys Plasmas, 2004, 11(2):339-491. 被引量:1
  • 2Stoeckl C, Glebov V Y, Roberts S, et al. Ten-inch manipulator-based neutron temporal diagnostic for cryogenic experiments on OMEGA[J]. Rev Sci Instrum, 2003, 74(3):1713 -1716. 被引量:1
  • 3Lerche R A, Cable M D. Fusion reaction rate measurement Nova and N1F[R]. UCRL-LR 105821- 98- 3, 1996. 被引量:1
  • 4Moran M J, Lerche R A, G Mant. Optical lightpipe as a high -band width fusion diagnostic[J]. Rev Sci Inslrum, 2006, 77: 10E718. 被引量:1
  • 5Mack J M, Caldwell S E, Evans S C, et al. Multiplexed gas Cherenkov detector for reaction-history measurements[J].Rev Sci Instrum, 2006, 77:10E728. 被引量:1
  • 6Lerche R A, Phillion D W, Tietbohl G L. 25 ps neutron detector for measuring ICF target burn history[J].Rev Sci Instrum, 1995, 66( 1 ) : 933-935. 被引量:1
  • 7曹顿华,刘永建,赵广军,陈建玉,董勤,丁雨憧.掺铈铝酸钇闪烁晶体自吸收问题研究[J].光学学报,2009,29(12):3463-3466. 被引量:8
  • 8宁家敏,蒋世伦,徐荣昆,郭存.强脉冲软X光辐照薄塑料闪烁体发光特性研究[J].强激光与粒子束,2006,18(7):1215-1218. 被引量:14

二级参考文献17

  • 1邱爱慈.脉冲X射线模拟源技术的发展[J].中国工程科学,2000,2(9):24-28. 被引量:32
  • 2徐荣昆,李正宏,杨建伦,许泽平,丁宁,郭存,蒋世伦,宁佳敏,夏广新,李林波,宋风军,陈进川.Study of tungsten wire array Z-pinch implosion on Qiang-Guang I facility[J].Chinese Physics B,2005,14(8):1613-1617. 被引量:7
  • 3朱江,赵广军,刘德安,李红军,徐军.新型光折变晶体Mn:YAP研究进展[J].激光与光电子学进展,2006,43(7):60-63. 被引量:2
  • 4K. Hirota, H. Toyokawa, M. Suzuki et al.. A YAP(Ce) imager operated in high energy X-ray region[J]. Nucl. Instr. Meth. A, 2001, 4674468(2): 1121-1124. 被引量:1
  • 5W. Klamra, A. Kerek, M. Moszyski et al.. Response of BaF2 and Ce:YAP to heavy ions[J]. Nucl. Instr. Meth. A, 2000, 444(3) : 626-630. 被引量:1
  • 6E. Siunga, B. Cederwall, E. Ideguchi et al.. Scintillation response of BaF2 and YAlO3: Ce (Ce: YAP) to energetic ions[J]. Nucl. Instr. Meth. A, 2001, 469(1): 70-76. 被引量:1
  • 7S. Baccaro, K. Blazek, F. de Notaristefani. Scintillation properties of Ce:YAP [J]. Nucl. Instr. Meth. Phys. Res. A, 1995, 361(1): 209-215. 被引量:1
  • 8M. Tardocchi, G. Gorini, A. Pietropaolo et al.. YAP scintillators for resonant detection of epithermal neutrons at pulsed neutron sources [J]. Rev. Sci. Instrum. , 2004, 75(11): 4880-4890. 被引量:1
  • 9G. S. Li, J. H. Wu, Y. Chen et al.. Growth of high quality Ce^3+ : YAP and (Ce^3+ +Nd^3- ) : YAP single crystals[J]. Chinese J. Lasers B, 1993, 2(1): 91-96. 被引量:1
  • 10M. J. Weber, M. Bass, K. Andringa. Czochralski growth and properties of YAlO3 laser crystals[J]. Appl. Phys. Lett. , 1969, 15(10) : 342-345. 被引量:1

共引文献17

同被引文献52

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部