期刊文献+

相衬照相法检测聚苯乙烯微球气泡缺陷 被引量:1

Inspecting micro-bubble in polystyrene shell using phase-contrast imaging
下载PDF
导出
摘要 利用较高能量的X射线对聚苯乙烯(PS)微球进行离焦相衬成像,球壁内密度变化较大的微小气泡的边缘衬度得到有效增强,从而在灰度变化较平滑的微球整体图像中凸显出来,分析了衬度来源及相关因素。实验采用微焦斑的X射线管及CCD作为光源及探测器,图像分辨力约为2μm,在能量为20~30keV时,实现了PS微球缺陷快速检测,为微球制备工艺的改善和提高提供了快速有效的监测手段。 Using high energy X-ray defocus phase contrast imaging on polystyrene(PS) microspheres, the contrast of the edge of tiny bubbles (about a few micrometers in diameter) in the sphere's wall are effectively enhanced, where the density gradi ent is relatively larger, and thus the bubbles will be highlighted on the image of microsphere which has overall smooth gray scale. The contrast causing and related factors are analyzed and discussed. The experiments conducted use micro-focal spot X ray tube and CCD as the light source and detector, the derived image resolution is better than 2μm, and the rapid defect detection of PS shells is achieved at the X-ray energy of 20 to 30 keV, providing a fast and effective means for moniloring of microspheres prepa ration process.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2011年第8期2097-2100,共4页 High Power Laser and Particle Beams
基金 国家高技术发展计划项目
关键词 PS微球 相位物体 微气泡缺陷 相衬照相 polystyrene shell phase object micro-bubble phase contrast imaging
  • 相关文献

参考文献11

二级参考文献57

共引文献63

同被引文献11

  • 1Nesterets Ya I, Wilkins S W, Gureyev T E, et al. On the optimization of experimental parameters for X-ray in-line phase-contrast imaging [J]. Review of Scientific Instruments, 2005, 76: 093706. 被引量:1
  • 2Peterzol A, Berthier J, Duvauchelle P, et al. X-ray phase contrast image simulation[J]. Nuclear Instruments and Methods in Physics Re- search B, 2007, 254: 307-318. 被引量:1
  • 3Snigirev A, Snigireva I, Kohn V, et al. On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radia- tion[J]. Review of Scientific Instruments, 1995, 66(12) : 5486-5492. 被引量:1
  • 4Cowley J M. Diffraction physics[M]. Amsterdam: North Holland, 1995. 被引量:1
  • 5Duvauehelle P, Freud N, Kaftandjian V. A computer code to simulate X-ray imaging techniques[J]. Nuclear Instruments and Methods in Physics Research, 2000, 170.. 245-258. Yadav P S, Kashyap Y, Sarkar P S, et al. Study of phase contrast imaging for carbon fiber, polystyrene and lung tissue using monochro- matic and polychromatic X-ray sources~J]. Nuclear Instruments and Methods in Physics Research A, 2006, 564: 497-505. 被引量:1
  • 6Pogany A, Gao D, Wilkins S W. Contrast and resolution in imaging with a microfocus X-ray source[J]. Reviezoof Scientific Instruments, 1997, 68: 2774-2782. 被引量:1
  • 7Pogany A, Gao D, Wilkins S W. Contrast and resolution in imaging with a microfocus X-ray source[J]. Reviewof Scientific Instruments, 1997, 68: 2774-2782. 被引量:1
  • 8顾牡,李达,倪晨,刘小林,刘波,黄世明.双层塑料靶丸的X射线相衬成像[J].强激光与粒子束,2009,21(10):1481-1484. 被引量:4
  • 9曹宇东,祁双喜,叶雁,李泽仁.X射线同轴相衬成像的参数优化系统[J].强激光与粒子束,2010,22(10):2267-2270. 被引量:2
  • 10曹宇东.基于图像信噪比的X射线同轴相衬成像系统设计[J].强激光与粒子束,2013,4(4):1021-1025. 被引量:2