期刊文献+

空间“十”字配准脊柱手术机器人导航方法 被引量:1

The space "十" registration method for a self-designed spinal surgery navigation robot
下载PDF
导出
摘要 背景:现有用于椎弓根置入的脊柱手术机器人都要依赖计算机辅助导航系统进行定位和姿态控制,这样计算机辅助导航系统的不足在它们身上都会有体现。包含计算机辅助导航系统的手术机器人,不仅构成复杂,椎弓根置入的精度也难以进一步提高。目的:探索空间"十"字配准导航方法,控制自主研制的脊柱手术机器人进行更为精准、高效和安全的椎弓根置入。方法:将依据CT测量值设置的机器手的2枚导针置于两椎弓根中心轴线置入点上并通过X射线正侧位透视确定。令X射线设备的中心投照线先后与2枚导针的中心轴线重合,再从椎弓根轴位进行投照,使体外与体内"十"字配准,定位椎弓根峡部中心点(以下简称中心点)。依据"两点定一线"的原理,使导针通过两椎弓中心轴线置入点和椎弓根峡部中心点,脊柱导航手术机器人即可沿椎弓根中心轴线准确置入。依据规划置入点和置入线相应偏离两椎弓中心轴线置入点的距离和椎弓根中心轴线的角度,完成上述两点的确定或定位后,重新设置两导针中心轴线针尖水平之间的距离及夹角,同样"十"字配准后即可按规划路径准确置入。结果与结论:"十字配准、两点一线"的导航原理可引导脊柱手术机器人沿椎弓根中心轴线或规划路径准确置入,从而为脊柱手术机器人确定了新的、更为准确高效的导航方法。 BACKGROUND:The transpedicular placement used by spinal surgery robot must depend on the computer aided surgery navigation system(CASNS) at present.Due to the disadvantages of the CASNS,the robot not only has complexity in structure,but also difficulty of further improving the insertion accuracy.OBJECTTIVE:To analyze the value of the external and internal AS registration method for improving the insertion accuracy of the self-designed spinal navigation surgery robot.METHODS:According to the data measured on CT scanning,the distance and angle of the two guide wires of the manipulator were set,and its needlepoint locating at the two pedicle central axis(PCA) entry points(EP) were confirmed by the lateral and anteroposterior fluoroscopy.After the two central axis of guide wire and central view axis of C-Arm were coincided respectively,the pedicle axis view was acquired via C-arm,the external "十" was adjusted to register with the internal "十",then the centre of pedicle isthmus(CPI) was confirmed.Depending on the principle two points making a line,the insertion along the PCA was achieved by the robot when the guide wire was inserted through the EP and CPI.Similarly,after the EP and CPI was confirmed,the two guide wires were reset in accordance with the distance and angle deviating from the EP and PCA measured on CT scanning,it was inserted along the palnned trajectory accurately.RESULTS AND CONCLUSION:Depending on the principle of the external and internal "十" registration and two points making a line,the guide wire can be inserted along the PCA or the planned trajectory,which provides a new and efficient method of improving the accuracy for the spinal surgery navigation robot.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2011年第17期3124-3126,共3页 Journal of Clinical Rehabilitative Tissue Engineering Research
  • 相关文献

参考文献16

  • 1Barzilay Y,Liebergall M,Fridlander A,et al.Miniature robotic guidance for spine surgery--introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres.Int J Med Robot.2006; 2(2):146-153. 被引量:1
  • 2Sukovich W,Brink DS,Hardenbrook M,et al.Miniature robotic guidance for pedicle screw placement in posterior spinal fusion:early clinical experience with the SpineAssist.Int J Med Robot.2006;2(2):114-122. 被引量:1
  • 3Lieberman IH,Togawa D,Kayanja MM,et al.Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement:Part I--Technical development and a test case result.Neurosurgery.2006;59(3):641-650. 被引量:1
  • 4Togawa D,Kayanja MM,Reinhardt MK,et al.Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement:part 2--Evaluation of system accuracy.Neurosurgery.2007;60(2 Suppl 1):ONS129-139. 被引量:1
  • 5Chung GB,Kim S,Lee SG,et al.An image-guided robotic surgery system for spinal fusion.Int J Control Auto Sys.2006;4(1):30. 被引量:1
  • 6Chung GB,Kim S,Yi BJ,et al.Cadaver Study for Spinal Fusion Surgery Using an Image-guided Surgical Robotic System.International Journal of Control Automation and Systems.2010; 8(3):564-573. 被引量:1
  • 7Lee F,Hwang I,Kim K,et al.Cooperative robotic assistant with drill-by-wire end-effector for spinal fusion surgery.Ind Robot:An int J.2009;1(36):60-72. 被引量:1
  • 8Zemiti N,Morel G,Ortmaier T,et al.Mechatronic Design of a New Robot for Force Control in Minimally Invasive Surgery.IEEE/ASME TRANSACTIONS ON MECHATRONICS.2007; 11(12):143-147. 被引量:1
  • 9Hussong A,Rau TS,Ortmaier T,et al.An automated insertion tool for cochlear implants:another step towards atraumatic cochlear implant surgery.Int J Comput Assist Radiol Surg.2010;5(2):163-171. 被引量:1
  • 10Ortmaier T,Weiss H,Dobele S,et al.Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placement.Int J Med Robot.2006;2(4):350-363. 被引量:1

二级参考文献58

共引文献92

同被引文献13

  • 1黄东生,苏培强,马若凡,李春海,彭焰,刘尚礼.颈椎椎弓根螺钉瞄准器的研制与实验[J].中国医学科学院学报,2005,27(2):156-159. 被引量:6
  • 2毛广平,赵建宁,王与荣,陈跃先,黎介寿,邱大学.三维定位器置钉方法的研究[J].中国矫形外科杂志,2005,13(18):1404-1407. 被引量:11
  • 3Jones EL,Heller JG,Silcox DH. Cervical pedicle screws versus lateral mass screws.Anatomic feasibility and biome-chanical comparison[J].{H}SPINE,1997,(09):977-982. 被引量:1
  • 4Abumi K,Itoh H,Taneichi H. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine:description of the techniques and preliminary report[J].{H}Journal of Spinal Disorders,1994,(01):19-28. 被引量:1
  • 5Tofuku K,Koga H,Komiya S. Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina[J].Eur Spine,2012,(02):353-358. 被引量:1
  • 6Neo M,Fujibayashi S,Miyata M. Vertebral artery injury during cervical spine surgery:a survey of more than 5600 operations[J].{H}SPINE,2008,(07):779-785. 被引量:1
  • 7Jeanneret B,Gebhard JS,Magerl F. Transpedicular screw fixa-tion of articular mass fracture-separation:results of an anatom-ical study and operative technique[J].{H}Spinal Disorder,1994,(03):222-229. 被引量:1
  • 8Abumi K,Shono Y,Ito M. Complications of pedicle screw fixation in reconstructive surgery of the cervical spine[J].{H}SPINE,2000,(08):962-969. 被引量:1
  • 9Yukawa Y,Kato F,Yoshihara H. Cervical pedicle screw fixation in 100 cases of unstable cervical injuries:pedicle axis views obtained using fluoroscopy[J].{H}Journal of Neurosurgery-Spine,2006,(06):488-493. 被引量:1
  • 10王东来,唐天驷,黄士中,杨惠林,邵云伟.下颈椎椎弓根内固定的解剖学研究与临床应用[J].中华骨科杂志,1998,18(11):659-662. 被引量:93

引证文献1