摘要 本文根据低剂量CT投影数据的噪声特性,提出了一种基于小波变换的低剂量CT投影数据三维块匹配(BM3D)滤波方法。新方法首先对经过Anscombe变换的低剂量CT投影数据进行小波分解,然后分别对分解后尺度系数和小波系数进行BM3D滤波,接着对滤波后的系数进行逆小波变换和Anscombe逆变换,最后对处理后的投影数据采用经典的滤波反投影(FBP)算法完成图像重建。实验表明,本文方法在噪声抑制和图像细节保持等方面均有上佳表现。 According to the property of the low-dose CT projection noise,this paper propose a wavelet-transform based low-dose CT projection BM3D Filtering(Block-Matching and 3D filtering)technique.For the proposed method,first,low-dose projection data is decomposed by Haar-wavelet transform after Anscombe transform.And then the efficient BM3D algorithm is performed separately in the scale coefficient and the wavelet coefficients.Next,the filtered coefficients are transformed orderly by inverse Anscombe transform and inverse Haar-wavelet transform.Finally,the reconstruction image is achieved by the classical filtered back projection(FBP)method.Simulated and clinical data experimental results demonstrate that the proposed method can do well in noise suppression and detail preservation of the reconstructed image.
出处 《CT理论与应用研究(中英文)》 2011年第2期163-171,共9页 Computerized Tomography Theory and Applications
基金 国家重点基础研究发展计划(973计划)(2010CB732503) 国家自然科学基金(81000613)
关键词 小波变换 BM3D滤波 低剂量CT Wavelet transform BM3D filtering low-dose CT
  • 相关文献

参考文献20

  • 1Donnelly LF, Emery KH, Brody AS, et al. Minimizing radiation dose for pediatric body application of single-detector helical CT: Strategies at a large children's hospital[J]. American Journal of Roentgenology, 2001, 176(2): 303-306. 被引量:1
  • 2Rust GF, Reiser M, Aurich V. Noise/dose reduction and image improvements in screening virtual colonoscopy with tube currents of 20MAS with nonlinear Gaussian filter chains[C]//Proc. SPIE Medical Imaging, 2002: 186-197. 被引量:1
  • 3MendrikAM, Vonken EJ, Rutten A, et al. Noise reduction in computed tomography scans using 3-d anisotropic hybrid diffusion with continuous switch[J]. IEEE Transactions Medical Imaging, 2009, 28(10): 1585-1594. 被引量:1
  • 4Kelm ZS, Blezek D, Bartholmai B, et al. Optimizing non-local means for denoising low dose CT[C]. Proceedings of the Sixth IEEE international conference on Symposium on Biomedical Imaging, Boston, MA. 2009: 662-665. 被引量:1
  • 5Hsieh J. Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise[J]. Medical Physics, 1998, 25(11): 2139-2147. 被引量:1
  • 6Lu HB, Li X, Li LH, et al. Adaptive noise reduction toward low-dose computed tomography[J]. SPIE Physics of Medical Imaging, 2003, (5030): 759-766. 被引量:1
  • 7Manduca A, Yu LF, Trzasko JD, et al. Projection space denoising with bilateral filtering andCTnoisemodeling for dose reduction inCr[J]. Medical Physics, 2009, 36(11): 4911-4919. 被引量:1
  • 8Donoho DL, Johnstone JM. Ideal spatial adaptation via wavelet shrinkage [J]. Biometrika, 1994, 81(3) : 425-455. 被引量:1
  • 9Donoho DL, Johnstone JM. Adapting to unknown smoothness via wavelet shrinkage[J]. Journal of the American Statistical Assoc, 1995, 90(12): 1200-1224. 被引量:1
  • 10Chang SG, Yu B, Vetterli M. Adaptive wavelet thresholding for image denoising and compression[J]. IEEE Transactions on Image Processing: A Publication of the IEEE Signal Processing Society, 2000, 9(9): 1532-1546. 被引量:1

二级参考文献2

共引文献9

同被引文献32

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部