Study on Electromagnetic Environment of AC-DC Hybrid Transmission Lines

Study on Electromagnetic Environment of AC-DC Hybrid Transmission Lines
下载PDF
导出
摘要 With the expansion of electricity demand,transmission corridors are becoming scarce.AC and DC circuits running parallel to each other and sharing the same right-of-way or even the same tower become a possible option.Due to the existence of the adjacent line,space electromagnetic field and corona of another line may be changed.Different characteristics of two line types make the electromagnetic field of transmission corridors become more complex.Hybrid line is viewed as a whole.The calculation contains surface gradient,ground level electric field,radio interference and audible noise.Interaction between the two line types is considered.The calculation results show that the interaction is mainly concentrated in the inner corridor.In the role of DC electric field,AC electric field is no longer symmetrical and ground level electric field is significantly enhanced.Under the negative DC voltage,the positive corona of the waveform is significantly strengthened,and it is inhibited under the positive DC voltage.It is better to erect the positive DC line near AC line. With the expansion of electricity demand, transmission corridors are becoming scarce. AC and DC circuits running parallel to each other and sharing the same right-of-way or even the same tower become a possible option. Due to the existence of the adjacent line, space electromagnetic field and corona of another line may be changed. Different characteristics of two line types make the electromagnetic field of transmission corridors become more complex. Hybrid line is viewed as a whole. The calculation contains surface gradient, ground level electric field, radio interference and audible noise.. Interaction between the two line types is considered. The calculation results show that the interaction is mainly concentrated in the inner corridor. In the role of DC electric field, AC electric field is no longer symmetrical and ground level electric field is significantly enhanced. Under the negative DC voltage, the positive corona of the waveform is significantly strengthened, and it is inhibited under the positive DC voltage. It is better to erect the positive DC line near AC line.
出处 《高压电器》 CAS CSCD 北大核心 2011年第9期26-30,共5页 High Voltage Apparatus
关键词 hybrid corridor surface gradient radio interference audible noise hybrid corridor surface gradient radio interference audible noise
  • 相关文献

参考文献11

  • 1CLAIRMONT B A, JOHNSON G B, ZAFFANELLA L E, et al. The effect of HVAC-HVDC line separation in a hybrid corridor[J]. IEEE Transactions on Power Delivery, 1989,4(2): 1338-1350. 被引量:1
  • 2CHARTIER V L, SARKINEN S H, STEARNS R D, et al. Investigation of corona and field effects of AC/DC hybrid transmission lines[J]. IEEE Transactions on Apparatus and System, 1981, 100(1): 72-80. 被引量:1
  • 3IEEE Corona and Field Effects Sub Committee Report Radio Noise Working Group. A survey of methods for calculating transmission line conductor surface gradients[J]. IEEE Transactions on Apparatus and System, 1979, 98(6): 1996-2007. 被引量:1
  • 4SARMA M P,JANISCHEWSKYJ W.Electrostatic field of a system of parallel cylindrical conductors[J]. IEEE Transactions on Power Apparatus and Systems, 1969, 88(7): 1069-1079. 被引量:1
  • 5MARUVADA P S, DROGI S. Field and ion interactions of hybrid AC/DC transmission lines[J]. IEEE Transactions on Power Delivery, 1988, 3(3): 1165-1172. 被引量:1
  • 6DUT 691-1999. Methods of calculation of radio interference from high voltage overhead power transmission lines[S]. 被引量:1
  • 7Electric Power Research Institute. Transmission line reference book, 345 kV and above[M]. USA: Fred We:dner & Son Printers, 1982. 被引量:1
  • 8ANIS H, ZEITOUN A. Field calculations around non-standard electrodes using regression and their spherical equivalence[J]. IEEE Trans. on Power Apparatus and Systems, 1977, 96(11):17-21. 被引量:1
  • 9GOLSEN R. Radio noise due to corona on a multiconductor power line above a dissipative earth[J]. IEEE Transactions on Power Delivery, 1988, 3(1):272-287. 被引量:1
  • 10YANG Jie, LU Tie-bing. Study on ionized field under hybrid HVDC and HVAC power transmission lines [C]// Automation Congress. Hawaii :IEEE ,2008:1-4. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部