期刊文献+

320排容积CT上腹部一站式检查初步探讨 被引量:20

Nitial Experience of Upper Abdomen One-stop Examination with 320 Detector Row CT
原文传递
导出
摘要 目的探讨320排容积CT在全上腹部器官扫描中的优势及临床应用价值。资料与方法 96例患者注射对比剂后,利用Toshiba 320排CT进行上腹部容积扫描。将数据导入Toshiba体部灌注软件对全上腹部器官进行灌注分析,同时选择最佳时相重组平扫、增强各期图像,重组动脉CT血管造影(CTA)、静脉及门静脉CT静脉成像(CTV)。并分组对一站式检查进行辐射剂量分析。结果 89例获取良好的平扫及多期增强容积图像、动态DSA图像、门静脉CTV以及全上腹部低剂量灌注图像。连续动态成像提示动脉期成像最佳时间点分布于19~22 s之间,门静脉最佳成像时间点分布于33~36 s之间。其中发现合并或单发血管病变累计57处;发现合并或单发上腹部器官异常灌注72处;剂量对比发现辐射剂量轻度增加。结论 320排容积CT上腹部一站式检查可以动态观察所有脏器平扫至增强各期血流灌注情况,同时对病灶本身、整个脏器及邻近脏器灌注情况进行定性、定量分析,能排除个体差异影响,准确选择最佳时相显示动脉、静脉系统血管形态及动态血流信息,真正实现了上腹部一站式容积扫描,对于上腹部病变具有极高的临床诊断价值。 Objective To evaluate the clinical advantage and value of upper abdominal one-stop examination with 320 detector row CT.Materials and Methods After having injected the contrast medium,dynamic volume scanning was performed for all 96 patients with Toshiba 320 detector row CT for upper abdominal organs one stop examination.The data were analyzed with Toshiba body perfusion software.The plain and contrast axial thick layer images,CTA,vein and Portal vein CTV were recombined by selecting the data of optimal time phase.Results 89 cases obtained good quality images of plain and contrast,CTA,vein and portal vein CTV,upper abdominal organs perfusion.The dynamic enhanced imaging showed that the optimal time point of arterial phase and portal vein phase distributed in 19.0-22.0 s,33.0-36.0 s respectively.Using these time points,we found vascular diseases in 57 cases,abnormal perfusion in 72 cases.Conclusion Upper abdominal one stop examination using 320 detector row CT can show the anatomy and dynamic blood flow information of organs,vessels exactly by selecting the optimal time phase,which has important clinical value in diagnosis of upper abdominal diseases.
出处 《临床放射学杂志》 CSCD 北大核心 2011年第8期1206-1210,共5页 Journal of Clinical Radiology
基金 四川省卫生厅科研课题(编号:090007)
关键词 体层摄影术 X线计算机血管造影术灌注 Tomography X-ray computed Angiography Perfusion
  • 相关文献

参考文献13

二级参考文献33

  • 1石献忠,韩卉,赵靖.筛窦外侧壁显微外科解剖学[J].解剖学杂志,2005,28(3):347-348. 被引量:7
  • 2潘振宇,钱晓军,翟仁友,顾华.筛动脉管的CT影像解剖学研究及其临床意义[J].中国医学影像技术,2006,22(8):1185-1188. 被引量:8
  • 3Dewey M. Noninvasive Coronary A ngiography by 320-Row Computed Tomography with Lower Radiation Exposure and Maintained Diagnostic Accuracy[J]. Circulation,2009,120: 867-875. 被引量:1
  • 4J Geleijns. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting:Technical note[J]. Phys. Med. Biol,2009, 54: 3 141-3 159. 被引量:1
  • 5John Hoe,MBBS,DMRD,et al. First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose [J]. Journal of Cardiovascular Computed Tomography, 2009 (5):257-261. 被引量:1
  • 6Steigner ML,Otero HJ,Cai T,et al. Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography[J]. The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging) ,2009,25 ( 1 ):85- 90. 被引量:1
  • 7Marc Dewey, Elke Zimmermann, Michael Laule,et al.Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography[J], AJR ,2009,193 : 1 514-1 521. 被引量:1
  • 8Sundeep S. Pasricha,Dee Nandurkar,Sujith K. Seneviratne, et al. Image Quality of Coronary 320-MDCT in Patients With Atrial Fibrillation[J]. Initial Experience ,2009,193 : 1 514-1 521. 被引量:1
  • 9Sonja Kandel,Christian Kloeters,Henning Meyer,et al.Wholeorgan perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma:acquisition technique, post-processing and initial results[J]. European Radiology,2009, 19(11): 2 641-2 646. 被引量:1
  • 10E SIEBERT,MD G BOHNER,MD M DEWEY,et al. 320-slice CT neuroimaging:initial clinical experience and image quality evaluation[J]. British Journal of Radiology, 2009,82 : 561-570. 被引量:1