摘要
从输电铁塔塔上光通信中继站(以下简称中继站)的荷载和安装尺寸两个方面,对在输电铁塔塔上设置中继站的可行性进行分析,分析表明对于500 kV和±600 kV输电线路,均可在铁塔上设置中继站。以±600 kV宁东直流工程中的ZP2712直线塔上设置中继站为例,介绍了塔上中继站的设计,供工程参考。
The feasibility of aerial relay station on transmission tower is discussed on aerial relay station's load and installation dimension,aerial relay station can be installed on 500 kV and ±600 kV transmission tower.Taking example by aerial relay station installed on ZP2712 tower in ±600 kV Ningdong power transmission project,design of aerial relay station on transmission tower is introduced for engineering reference.
出处
《山东电力技术》
2011年第4期7-10,共4页
Shandong Electric Power
关键词
输电铁塔
中继站
设计
aerial relay station
transmission tower
design