摘要
介绍了隔膜计量泵的结构及工作原理,对该设备应用于氯气处理工序输送98%(质量分数)H2SO4过程中可能出现的问题进行了探讨和分析,并提出了解决方法。
The structure and working principle of metering diaphragm pumps are introduced.The potential problems are discussed and analyzed when the equipment is used in transporting 98%(wt) H_2SO_4 in chlorine treatment process.The countermeasures are proposed.
出处
《氯碱工业》
CAS
2011年第7期33-35,38,共4页
Chlor-Alkali Industry
关键词
氯气干燥
硫酸输送泵
隔膜计量泵
故障分析
chlorine gas drying
sulfuric acid pump
metering diaphragm pump
failure analysis