摘要
对KCWL系列离心机控制电路进行改进,增加了对三通调节阀的控制电路,实现了离心机正常停机或故障停机时控制三通调节阀自动切换到旁通管路的功能。
The KCWL serial centrifuge control circuit is improved.The control circuit of three way control valve is added.The function of auto switch of the three way control valve to the bypass line when the centrifuge is halt is implemented.
出处
《自动化应用》
2011年第6期34-35,共2页
Automation Application
关键词
离心机
控制电路
三通调节阀
电磁阀
自动切换
centrifuge
control circuit
three way control valve
Electromagnetic Valves
Auto-switch