摘要
结合一SF_6断路器灭弧室的设计讨论了电场计算在灭弧室绝缘设计中的应用.得到了影响灭弧室电场分布的主要因素并提出了改善电场分布的有效方法.计算和试验结果基本相符.
The electric field calculation is used for the insulation design of SF6 circuit breaker arc-extinguishing chamber. The main factors affecting the electric field distribution are obtained and the methods to improve the field distri-bution are presented. The calculated results are verified by the experiments.
出处
《高压电器》
CAS
CSCD
北大核心
1999年第6期24-27,共4页
High Voltage Apparatus
关键词
灭弧室
绝缘
设计
电场计算
静电场
electric field, arc - extinguishing chamber, insulation, design