摘要
采用可调谐二极管激光器做探测光源,测量了超音速氧碘化学激光器增益谱线的精细结构,得到了各谱线相对强度的百分比。同时也推得了增益线宽与腔内温度。
Hyperfine gain spectrum of a chemical oxygen-iodine laser (COIL) is investigated experi-mentally. Six hyperfine lines are obtained in a COIL gain medium as well as an iodine absorption cell.Mean- while, gain profiles and cavity temperatures are calculated.
出处
《强激光与粒子束》
EI
CAS
CSCD
北大核心
1999年第5期517-520,共4页
High Power Laser and Particle Beams
基金
国家863激光技术领域资助