期刊文献+

MSCT尿路造影技术的临床应用价值 被引量:4

Clinical application value of MSCT urography techniques
下载PDF
导出
摘要 目的探讨MSCT尿路造影技术的临床应用价值。方法回顾性分析有临床症状并行CT尿路造影的病例50例,通过常规平扫、动脉期、静脉期、延迟期扫描将所获得的数据进行MPR、MIP、CPR及VR三维重建。然后对获得的影像进行分析。结果所有病例均可成功重建出双肾、输尿管和膀胱的三维图像,能够通过旋转、放大等清晰显示全尿路及其局部细微结构、形态、走形及与周围组织的关系。结论通过MSCT对全尿路的适当扫描,对采集的数据进行各种三维重建,能够大大提高病灶检出的阳性率和诊断率。 Objective To study the clinical application value of MSCT urography techniques.Methods 50 cases of clinical symptomatic complicated with CT urography were retrospectively analyzed;MPR,MIP,CPR and VR 3d reconstruction were performed based on the data extracted by conventional plain scan,arterial phase,venous phase and lag period scan,then analyzed the image results.Results The bilateral renal,ureter and bladder 3d images can successfully rebuild for all cases.Urinary tract and its fine structure,form and the spatial relationship with surrounding tissue can clear display by rotation and magnification function.Conclusion Reconstruction of the data extracted by MSCT urinary tract scan can effectively improve the positive rate of nidus and the diagnostic rate.
出处 《临床军医杂志》 CAS 2011年第3期559-561,共3页 Clinical Journal of Medical Officers
关键词 多层螺旋CT 泌尿系统 三维成像 CT尿路造影 multi-slice spiral computed tomography urinary system 3d imaging CT urography
  • 相关文献

参考文献6

  • 1Kemper J,Adam G,Nolte-Ernsting C.Modern diagnostic assess-ment of the upper urinary tract using multislice CT urography[J].Rofo,2006,178(11):1086-1094. 被引量:1
  • 2Nolte-Ernsting C,Cowan N.Understanding multislice CT urography techniques:Many roads lead to Rome[J].Eur Radiol,2006,16(12):2670-2686. 被引量:1
  • 3Korogi Y,Takahashi M,Ogura Y,et al.Intracra-nial aneurysms:detection with reedimensional CT angiography with volume renderingconparision with conventional angiographic andsurgical findings[J].Radiology,1999,211(2):497. 被引量:1
  • 4张追阳,沈袁良,李新,曹荣妹,许锡淇,董坚,华冬英.CT尿路造影对非结石性尿路梗阻疾病的诊断作用[J].中华放射学杂志,2004,38(10):1099-1101. 被引量:34
  • 5王东,张挽时,熊明辉,喻敏,李相生,徐家兴.输尿管病变的螺旋CT评价[J].中华放射学杂志,2005,39(1):60-64. 被引量:76
  • 6Kawashima A,Vrtiska TJ,LcRoy AJ,et al.CT umgraphy[J].Radio Graphics,2004,z4(1):35-54. 被引量:1

二级参考文献13

  • 1Sudah M, Vannien RL, Partanen K, et al. Patients with acute flank pain: comparison of MR urography with unenhanced helical CT.Radiology, 2002, 223: 98-105. 被引量:1
  • 2McTavish JD, Jinzaki M, Zou KH, et al. Multi-detector row CT urography: comparison of strategies for depicting the normal urinary collecting system. Radiology, 2002, 225 : 783-790. 被引量:1
  • 3McNicholas MM, Raptopoulos VD, Schwartz RK. Excretory phase CT urography for opacification of the urinary collecting system. AJR,1998, 170: 1261-1268. 被引量:1
  • 4Caoili E, CoHan RH, Korobkin M, et al. Urinary tract abnormalities : initial experience with multi-detector row CT urography. Radiology, 2002, 222: 353-360. 被引量:1
  • 5McNicholas MM,Raptopoulos VD,Schwarts RK,et al.Excretory phase CT urography for opacification of the urinary collecting system.AJR,1998,170:1261-1267. 被引量:1
  • 6Heneghan JP,Kim DH,Leder RA,et al.Compression CT urography: a comparison with IVU in the opacification of the collecting system and ureters.J Comput Assist Tomogr,2001,25:343-347. 被引量:1
  • 7Smith RC,Rosenfield AT,Choe KA,et al.Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography. Radiology,1995,194:789-794. 被引量:1
  • 8Sudah M,Vanninen R,Partanen K,et al.MR urography in evaluation of acute flank pain: T2-weighted sequences and gadolinium-enhanced three-dimensional FLASH compared with urograhy.AJR,2001,176:105-112. 被引量:1
  • 9卢延,洪闻,陆立,王武,张雪哲.磁共振泌尿系造影对尿路梗阻性病变的诊断价值[J].中华放射学杂志,1999,33(9):617-620. 被引量:76
  • 10李建生,李康印,陈虎义,强海霞,沈国强,李静.螺旋CT及其泌尿系成像对输尿管病变的诊断价值[J].中华放射学杂志,2001,35(4):309-311. 被引量:61