期刊文献+

数字式测高仪的动态特性测试分析

Testing and Analysis of Dynamic Characteristics of Digital Height Measuring Instrument
下载PDF
导出
摘要 数字式测高仪的测量速度、定位精度和测量力是表征其动态特性的3个主要方面.为此,论述了它们的具体测量方法,以某数字式测高仪为对象,采用微平面镜激光干涉仪、精密测力计等器具进行动态特性测试,给出了测试结果,分析了误差来源及其变化规律,其中,对测高仪定位误差的测试与分析是新的尝试.测试结论对改进测高仪的设计、提高测量精度具有实际价值. Measuring speed,position accuracy and stylus force are three main dynamic characters of digital height measuring instrument(DHMI).Test methods of the three important characters are discussed.And some measuring instruments such as a miniature plane-mirror interferometer and a precise forcemeter are employed for testing these characters.Testing results are presented and the sources and regularity of dynamic errors are analyzed.It is innovative to test and analyze the position accuracy of DHMI.These important test data and conclusions can be utilized to improve the measuring accuracy of DHMI.
出处 《北京工业大学学报》 EI CAS CSCD 北大核心 2011年第6期801-805,共5页 Journal of Beijing University of Technology
基金 国家自然科学基金资助项目(50627501)
关键词 测高仪 动态响应 定位误差 测量力 digital height measuring instrument dynamic response positioning error stylus force
  • 相关文献

参考文献8

  • 1范天泉,陆德基,吴学巧,等.JJG929--98数显测高仪检定规程[S].北京:中国计量出版社,1998:5-6. 被引量:1
  • 2SCHWENKE H, KNAPP W, HAITJEMA H, et al. Geometric error measurement and compensation of machines--an update [J]. CIRP Annals-Manufacturing Technology, 2008, 57 (2) : 660-675. 被引量:1
  • 3CASTRO H F F, BURDEKIN M. Dynamic calibration of the positioning accuracy of machine tools and coordinate measuring machines using a laser interferometer [ J]. International Journal of Machine Tools and Manufacture, 2003, 43 (9) : 947-954. 被引量:1
  • 4CASTRO H F F, BURDEKIN M. Evaluation of the measurement uncertainty of a positional error calibrator based on a laser interferometer [ J ]. International Journal of Machine Tools and Manufacture, 2005, 45 ( 3 ) : 285- 291. 被引量:1
  • 5SIOS. Miniature plane-mirror interferometers user's guide [ M ]. Ilmenau, Germany: [ s. n. ], 1999: 52-53. 被引量:1
  • 6KHIAT A, LAMARQUE F, PRELLE C, et al. Two-dimension fiber optic sensor for high-resolution and long-range linear measurements[ J]. Sensors and Actuators A : Physical, 2010, 158 ( 1 ) : 43-50. 被引量:1
  • 7费业泰,赵静,王宏涛,马修水.三坐标测量机动态误差研究分析[J].仪器仪表学报,2004,25(z1):773-776. 被引量:22
  • 8WEEKERS W G, SCHELLEKENS P H J. Compensation for dynamic errors of coordinate measuring machines [J].Measurement, 1997, 20(3) : 197-209. 被引量:1

二级参考文献12

  • 1[2]Weekers W G, Schellekens P H J. Assessment of dynamic errors of CMMs for fast probing. Annals of the CIRP, 1995,45:197~209. 被引量:1
  • 2[5]Pereira P H. Dynamic error characteristic on scanning probe CMMs. Ph. D. Thesis ,University of North Carolina at Charlotte. 被引量:1
  • 3[6]Y. H. Mu, et al.. Dynamic error compensation of coordinate measuring machines for high-speed measurement.Journal of Advance Manufacturing Technology, 1999,810~814. 被引量:1
  • 4[7]W. Tyler Estler,et al.. Practical aspects of touch-trigger probe error compensation. precision engineering,1997,1~17. 被引量:1
  • 5[8]Q. Yang, et al.. Error compensation of touch trigger probes. Measurement, 18 (1): 47 ~ 57. 被引量:1
  • 6[9]James D. Destefani. CMMs. Manufacturing Engineering,2001, 9:101~105. 被引量:1
  • 7[10]W.G. Weekers,P. H. J. Schellekens. Compensation for Dynamic errors of coordinate measuring machines. 1997,20 (3) :197~209. 被引量:1
  • 8[11]C. Dong, et al.. Prediction and compensation of dynamic errors for coordinate measuring machines. ASME Transactions, 2002,124 (3): 509 ~ 514. 被引量:1
  • 9[12]Vermeulen M. M, et al.. Design of a High-precision 3D-Coordinate Measuring Machine. CIPR Ann. , 47 (1):447~450. 被引量:1
  • 10[13]Vim P. van Vliet,et al.. Development of a fast mechanical probe for coordinate measuring machines. Precision engineering, 1998,141 ~ 152. 被引量:1

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部