Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger 被引量:2

Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger
原文传递
导出
摘要 In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat ex changer.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第7期1668-1673,共6页 中国科学(技术科学英文版)
基金 supported by the Construction Technology Innovation Program from KICTEP (Grant No. 06CTIPD04) the National Research Foundation of Korea Grant funded by the Korean Government (Grant No. 2010-0011159)
关键词 closed-loop vertical ground heat exchanger cement grout bentonite grout in-situ thermal response test finite-volumemethod thermal conductivity 换热性能 数值模拟 热响应 垂直 闭环 测试 FLUENT 数值分析
  • 相关文献

参考文献1

二级参考文献12

  • 1Hyung Jin Shin,Seong Joon Kim.Assessment of climate change impact on snowmelt in the two mountainous watersheds using CCCma CGCM2[J]. KSCE Journal of Civil Engineering . 2007 (6) 被引量:1
  • 2Heiberger J A,Remund C P.Evaluation of the pumpability of ben-tonite-based grouts. Final Report TR-109163,Electric Power Research Institute . 1997 被引量:1
  • 3Choi H,Lee C,Gil H,et al.Experimental study on thermal conduc-tivity and viscosity of grouts for backfilling ground heat exchanger. J Korea Soc New and Renewable Energy . 2007 被引量:1
  • 4Shon B H,Shin H-J.Thermal conductivity measurement of grouting materials for ground heat exchanger borehole. J Soc of Air-Cond Refrig Eng Korea . 2006 被引量:1
  • 5Remund C P,Schafer V R,Stetson L E.Bentonite-based backfill mixtures for GSHPs. Final Report,RER Project 91-18,National Ru-ral Electric Cooperative Association . 1993 被引量:1
  • 6Choi H,Lee C,Choi H,et al.A study on the physical characteristics of grout material for backfilling Ground Heat Exchanger. J Korea Geotech Soc . 2008 被引量:1
  • 7KEMCO Annual Report 2006. . 2006 被引量:1
  • 8Standard Test Method for Swell Index of Clay Min-eral Component of Geosynthetic Clay Liners. ASTM D5890 . 1995 被引量:1
  • 9UNFCCC.Kyoto Protocol to the United Nations Framework Convention on Climate Change. FCCC/CP/1997/L.7/Add.1 . 1997 被引量:1
  • 10Mitchell J K.Fundamentals of soil behavior. . 1976 被引量:1

共引文献19

同被引文献85

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部