期刊文献+

投影数据恢复导引的PET图像滤波 被引量:1

Projection recovery guided PET images filtering
下载PDF
导出
摘要 为了提高正电子发射断层成像(Positron Emission Tomography,PET)重建图像质量,提出一种投影数据导引的PET图像优质重建方法。新方法利用恢复投影数据的重建图像冗余信息优化非局部均值权重。对投影数据进行恢复,采用传统的滤波反投影(Filtered Back Projection,FBP)法进行PET图像重建,利用非局部均值(Non-localmeans)的思想计算权值矩阵,利用该权值先验矩阵导引直接重建FBP图像的非局部均值滤波。仿真和临床PET数据实验表明,方法可以在满足临床应用的需求下,有效地改善PET重建图像质量。 A novel approach is proposed to improve PET image quality by a non-local means prior induced by projection recovery.The new method exploits the redundancy of information in the image reconstructed from the restored projection data by optimizing non-local weight.Firstly, the raw projection data is restored, and the PET image is reconstructed with conventional Filtered Back Projection(FBP).A weight matrix is calculated by the non-local means weighting formula,and then the direct reconstructed image is restored with a non-local means prior guided by this weight matrix.Simulated and clinical PET data experiment results demonstrate that the proposed method has an effective quality improvement to the PET image under the condition of meeting the clinical needs.
出处 《计算机工程与应用》 CSCD 北大核心 2011年第17期196-199,共4页 Computer Engineering and Applications
基金 国家自然科学基金重大项目No.30730036 No.81000613 国家重点基础研究发展规划(973)(No.2010CB732503)~~
关键词 正电子发射断层成像(PET)重建 图像恢复 非局部均值滤波 Positron Emission Tomography(PET) reconstruction image restoration non-local means filtering
  • 相关文献

参考文献16

  • 1Phelps M E.PET:molecular imaging and its biological applica-tions[M].New York:Springer-Verlag,2004. 被引量:1
  • 2Bertero M,Mol C D,Pike E R.Linear inverse problems withdiscrete data,I:general formulation and singular system analysis[J].Inverse Problems,1985,1 (4):301-330. 被引量:1
  • 3叶华俊,刘华锋,鲍超.正电子发射断层成像重建算法评述[J].生物医学工程学杂志,2002,19(3):496-499. 被引量:2
  • 4Ma J,Feng Q,Feng Y,et al.Generalized Gibbs priors based positron emission tomography reconstruction[J].Comput Biol Med,2010,40(6):565-571. 被引量:1
  • 5Chen Y,Feng Q,Shi P,et al.A novel nonlocal quadratic MRF prior model for positron emission tomography[C] //IEEE ISBI,2007:149-152. 被引量:1
  • 6Barker W C,Thada S,Dieckmann W.A GPU-accelerated implementation of the MOLAR PET reconstruction package[C] //IEEE NSS,2009:4114-4119. 被引量:1
  • 7Bing B,Smith A M.Fast 3D iterative reconstruction of PET images using PC graphics hardware[C] //IEEE NSS,2006:2787-2790. 被引量:1
  • 8Kao C M,Yap J T,Mukherjee J,et al.Image reconstruction for dynamic PET based on low-order approximation and restoration of the sinogram[J].IEEE Trans on Med Imaging,1997,16(6):738-749. 被引量:1
  • 9Kao C M,Wernick M N,Chen C T.Kalman sinogram restoration for fast and accurate PET image reconstruction[J].IEEE Trans on Nucl Sci,1998,45(6):3022-3029. 被引量:1
  • 10Abella M,Vaquero J J,Soto-Montenegro M L,et al.Sinogram bow-tie filtering in FBP PET reconstruction[J].Med Phys,2009,36(5):1663-1671. 被引量:1

二级参考文献19

  • 1[1]Chen CM. An efficient four-connected parallel system for PET image reconstruction. Parallel Computing, 1998; 24∶1499 被引量:1
  • 2[2]Linda K. Implementing and accelerating the EM algorithm for positron emission tomography. IEEE Trans Med Imaging, 1987; 6 (1)∶37 被引量:1
  • 3[3]Malcolm H, Richard SL. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging, 1994; 13(4)∶601 被引量:1
  • 4[4]Browne J, Pierro AR. A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography. IEEE Trans Med Imaging, 1996; 15(5)∶687 被引量:1
  • 5[5]Tanaka E. Current status and future prospect of positron emission tomography. Radioisotopes, 1997; 46(10)∶733 被引量:1
  • 6[6]Rogers JG. The theory of three-dimensional image reconstruction for PET. IEEE Trans Med Imaging, 1987; 6(3)∶239 被引量:1
  • 7[7]Kinahan PE. Fast iterative image reconstruction of 3D PET data. IEEE Nuclear Science Symposium Conference Record, 1996; 3∶1083 被引量:1
  • 8[8]Wang CX, Synyder WE, Bilbro G, et al. Performance evaluation of filtered backprojection reconstruction and iterative reconstruction methods for PET image. Computers in Biology and Medicine, 1998; 28 (1)∶13 被引量:1
  • 9RAZIFAR P, SANDSTROM M, SCHNIEDER H, et al. Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM[J]. Bio Medical Central: Medical Imaging, 2005(5):5. 被引量:1
  • 10GUPTA V, CHAN CHI CHIU, PUI TZE SIAN. A differential evolution approach for PET image denoising[C]. Lyon, France:29th annual international conference of the IEEE on engineering in medicine and biology society, 2007,4173-4176. 被引量:1

共引文献20

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部