期刊文献+

尿碘测定中质量控制图的应用探讨 被引量:1

Application of quality control chart in the determination of urinary iodine
原文传递
导出
摘要 目的 针对现行尿碘检测方法中测定误差因素多的特点,建立实验室内质量控制体系,确保检验数据的准确可靠.方法 收集日常检测中空白管吸光度值及标准物质检测值,计算均值、标准偏差、控制限、辅助线,以它们为线绘制空白管吸光度值控制图及相对误差控制图;用不同碘含量(高、中、低浓度)的试样测定结果,计算各组平均值、相对减差值、加权值、临界限(Rc)值,列出临界限Rc值控制表.结果 空白值吸光度控制限((x)±3sb)范围为1.183~1.553;精密度控制临界限Rc值在尿碘0-〈150 μg/L时为0.0883,150~300 μg/L时为0.0572;相对误差控制限(E+3se)为9.3%.结论 建立质量控制图可有效控制实验室内尿碘检测质量,保证尿碘测定结果的可靠性和真实性. Objective Establish a laboratory quality control system to ensure accurate and reliable test data and to contrapose the influence of error factors in current detection methods for urinary iodine measurement. Methods The results of reagent blank absorbance value and uric iodine standard materials were collected, then their relevant technical indexes such as mean, standard deviation, control limit, auxiliary line were worked out. Then the quality control chart of blank test and the relative error control chart were made base on these technical indexes. And different iodine concentrations (high, middle and low concentration) were tested and their mean,relative reduction difference value, weighted mean value and critical limit Rc value were calculated, and then critical limit Rc value precision control chart was made. Results The range of absorbance of blank control test was 1.183 to 1.553. And the limit of the accuracy control Rc value was 0.0883, 0.0572, respectively, when the concentrations of urinary iodine was 0~ 〈 150 μg/L and 150 ~ 300 μg/L. The control limit of the relative error was 9.3%. Conclusions The method of quality control chart could be satisfactorily applied to identify the quality of the analytical results of urine iodine, and ensure the results of the urine iodine reliable and authentic.
出处 《中国地方病学杂志》 CAS CSCD 北大核心 2011年第3期345-347,共3页 Chinese Jouranl of Endemiology
关键词 尿 实验室 质量控制 Urine Iodine Laboratories Quality control
  • 相关文献

参考文献4

二级参考文献14

  • 1阎玉芹,张亚平,刘列钧,刘嘉玉,李卫东,华基礼,陈祖培.尿中碘的过硫酸铵消化—砷铈催化分光光度测定方法[J].中国地方病学杂志,2004,23(6):582-585. 被引量:134
  • 2陈守健 鄂学礼 等.水质分析质量控制[M].北京:人民卫生出版社,1987.133. 被引量:11
  • 3WS/T 107-1999.尿碘的砷铈催化分光光度测定方法[S].[S].,.. 被引量:1
  • 4WS/T107-1999.尿碘的砷铈催化分光光度测定方法[S].[S].,.. 被引量:29
  • 5Pino S, Fang SL, Braverman LE. Ammunium persulfate:a new and safe method for measuring urinary iodine by ammonium persulfate oxidation. Exp Clin Endocrinol Diabetes, 1998,106(suppl 3):22-27. 被引量:1
  • 6Sullivan KM, May S, Maberly GM. Urinary Iodine assessment:a manual on survey and laboratory methods. 2nd. Atlanta (USA):PAMM/UNICEF, 2000. 35-45. 被引量:1
  • 7ICCIDD, UNICEF, WHO. Assessment of iodine deficiency disorders and monitoring their elimination: a guide for programme managers.Geneva,WHO/NHD, 2001, 73-75. 被引量:1
  • 8Suldin OP. Controversies in urinary iodine determinations. Clin Biochem, 2002, 35:575-579. 被引量:1
  • 9Allouch S, Lejeune PJ, Barbaria J, et al. Urinary iodine analysis:an alternative method for digestion of urine samples. Clin Chem,2004, 50:780-782. 被引量:1
  • 10张亚平,陈惠琴.氯酸温和消化尿碘测定法影响因素的研究[J].中华预防医学杂志,1997,31(3):172-173. 被引量:8