目的:用定量超声(QUS)测量胫骨超声速度(SOS),诊断骨质疏松症(OP)。方法:采用Soundscan2000超声仪测定28例绝经前正常女性(对照组),40例绝经女性。结果:对照组SOS显著高于绝经组,OP检出率两组间有极显著性差异(P<0.01),对照组为7%,绝经组为37.5%。结论:超声测量骨密度简便易行,安全有效,可用它监测妇女绝经后骨密度的变化情况。
Objective: Todetecttheultrasoundspeedwithinthetibiaanddiagnosetheosteoporosis(OP)byquantitativeultrasound(QUS). Methods:WTBZSoundscan2000ultrasonicinstrumentwasusedtodetecttheultrasoundspeedwithinthetibiain28premenopausalhealthywomen(controlgroup)and40postmenopausalwomen(menopausalgroup).ZResults: Thetibiaspeedofsound(SOS)inthecontrolgroupwassignificantlyhigherthanthatinthemenopansalgroup.TherewassignificantdifferenceinOPdetectableratesbetweenthetwogroups(P<001).TheOPdetectableratewas7%inthecontrolgroup,and375% inthemenopausalgroup. Conclusion:ZThesoundscanforBMDevaluationofpostmenopausalwomenissafeandvaluable.
出处
《滨州医学院学报》
1999年第3期232-233,共2页
Journal of Binzhou Medical University
关键词
定量超声
绝径妇女
骨密度
骨质疏松症
quantitativeultrasound
postmenopausalwomen
bonemineraldensity
osteoporosis