期刊文献+

Noise exposure assessment with task-based measurement in complex noise environment 被引量:2

Noise exposure assessment with task-based measurement in complex noise environment
原文传递
导出
摘要 Background Task-based measurement (TBM) is a method to assess the eight-hour A-weighted equivalent noise exposure level (LAeq. 8h) besides dosimeter. TBM can be better used in factories by non-professional workers and staffs.However, it is still not clear if TBM is equal or similar with dosimeter for LAeq.8h measurement in general. This study considered the measurement with dosimeter as real personal noise exposure level (PNEL) and assessed the accuracy of TBM by comparing the consistencies of TBM and dosimeter in LAeq.8h measurement.Methods The study was conducted in one automobile firm among 387 workers who are exposed to unstable noise.Dosimeters and TBM were used to compare the two strategies and assess the degree of agreement and causes of disagreement. Worker's PNEL was measured via TBM for noise; the real PNEL was also recorded. The TBM for noise was computed with task/position noise levels measured via sound level meter and workers' exposure information collected via working diary forms (WDF) filled by participants themselves. Full-shift noise exposure measurement via personal noise dosimeters were taken as the real PNEL. General linear model (GLM) was built to analyze the accuracy of TBM for noise and the source of difference between TBM for noise and real PNEL.Results The LAeq.8h with TBM were slightly higher than the real PNELs, except the electricians. Differences of the two values had statistical significance in stamping workers (P <0.001), assembly workers (P=0.015) and welding workers (P=0.001). The correlation coefficient of LAeq.8h with TBM and real PNELs was 0.841. Differences of the two results were mainly affected by real PNEL (F=11.27, P=0.001); and work groups (F=3.11, P <0.001) divided by jobs and workshops were also independent factors. PNEL of workers with fixed task/position ((86.53±8.82) dB(A)) was higher than those without ((75.76±9.92) dB(A)) (t=8.84, P <0.01). Whether workers had fixed task/position was a Background Task-based measurement (TBM) is a method to assess the eight-hour A-weighted equivalent noise exposure level (LAeq. 8h) besides dosimeter. TBM can be better used in factories by non-professional workers and staffs.However, it is still not clear if TBM is equal or similar with dosimeter for LAeq.8h measurement in general. This study considered the measurement with dosimeter as real personal noise exposure level (PNEL) and assessed the accuracy of TBM by comparing the consistencies of TBM and dosimeter in LAeq.8h measurement.Methods The study was conducted in one automobile firm among 387 workers who are exposed to unstable noise.Dosimeters and TBM were used to compare the two strategies and assess the degree of agreement and causes of disagreement. Worker's PNEL was measured via TBM for noise; the real PNEL was also recorded. The TBM for noise was computed with task/position noise levels measured via sound level meter and workers' exposure information collected via working diary forms (WDF) filled by participants themselves. Full-shift noise exposure measurement via personal noise dosimeters were taken as the real PNEL. General linear model (GLM) was built to analyze the accuracy of TBM for noise and the source of difference between TBM for noise and real PNEL.Results The LAeq.8h with TBM were slightly higher than the real PNELs, except the electricians. Differences of the two values had statistical significance in stamping workers (P <0.001), assembly workers (P=0.015) and welding workers (P=0.001). The correlation coefficient of LAeq.8h with TBM and real PNELs was 0.841. Differences of the two results were mainly affected by real PNEL (F=11.27, P=0.001); and work groups (F=3.11, P <0.001) divided by jobs and workshops were also independent factors. PNEL of workers with fixed task/position ((86.53±8.82) dB(A)) was higher than those without ((75.76±9.92) dB(A)) (t=8.84, P <0.01). Whether workers had fixed task/position was a
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第9期1346-1351,共6页 中华医学杂志(英文版)
基金 The study was supported by the grants from the National Natural Science Foundation of China (No. 30640085) and the National Institution of Health (USA) (No. 1 R010H008967-01A2).
关键词 task-based measurement noise OCCUPATION exposure assessment ACCURACY FEASIBILITY task-based measurement noise occupation exposure assessment accuracy feasibility
  • 相关文献

参考文献4

二级参考文献19

  • 1丁茂平,许真,战庆长,穆玉梅,艾延廷,张润秋,金永哲.工业脉冲噪声对工人听觉的损害[J].中华劳动卫生职业病杂志,1993,11(6):334-337. 被引量:5
  • 2Seymour JF,Presneill JJ.Pulmonary alveolar proteinosis.Am J Respir Crit Care Med 2002;166:215-235. 被引量:1
  • 3Chiba M.Concentrations of essential trace elements in blood and introduction of analytical techniques.Nippon Rinsho 1996;54:179-185. 被引量:1
  • 4Rosen SH,Castleman B,Liebow AA.Pulmonary alveolar proteinosis.N Engl J Med 1958;258:1123-1142. 被引量:1
  • 5Buechner HA,Ansari A.Acute silicoproteinosis.Chest 1969;55:274-284. 被引量:1
  • 6Miller RR,Churg AM,Hutcheon M,Lan S.Pulmonary alveolar proteinosis and aluminum dust exposure.Am Rev Respir Dis 1984;130:312-315. 被引量:1
  • 7Singh G,Katyal SL,Bedrossian CW,Rogers RM.Pulmonary alveolar proteinosis.Staining for surfactant apoprotein in alveolar proteinosis and in conditions simulating it.Chest 1983;83:82-86. 被引量:1
  • 8Xipell JM,Ham KN,Price CG,Thomas DP.Acute silicolipoproteinosis.Thorax 1977;32:104-111. 被引量:1
  • 9Brain JD,Valberg PA.Deposion of aerosol in the respiratory tract.Am Rev Respir Dis 1979;120:1325-1367. 被引量:1
  • 10Homma T,Ueno T,Sekizawa K,Tanaka A,Hirata M.Interstitial pneumonia developed in a worker dealing with particles containing indium-tin oxide.J Occup Health 2003;45:137-139. 被引量:1

共引文献46

同被引文献18

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部