摘要
介绍了离子膜烧碱生产装置DCS系统遭雷击后的处理过程,分析了故障发生的原因,提出了改进措施。
The process of the ionic membrane caustic soda production plant DCS system after being struck by lightning was described,the reasons for failure were analyzed and the improvement measures was proposed.
出处
《中国氯碱》
CAS
2011年第5期30-32,共3页
China Chlor-Alkali
关键词
DCS
雷击
故障
处理
改进
DCS
lightning
failure
treatment
improvement