期刊文献+

古建筑旧青砖回弹测强曲线的建立 被引量:9

On the Strength-rebound-curve of the Grey Brick from Ancient Buildings
下载PDF
导出
摘要 快速准确地对古建筑青砖进行检测是文物建筑保护工程中普遍关注的问题,选取广东珠江三角洲地区古建筑中具有代表性的60组青砖试件,按照行业标准《回弹仪评定烧结普通砖强度等级的方法》进行试验和数据分析,建立该地区古建筑旧青砖回弹专用测强曲线,为回弹法测试技术在该地区文物建筑保护工程中的应用提供了依据。 Quick and accurate testing on the old grey brick from ancient buildings was concerned in the heritage conservation project.In this research,60 groups of bricks from the ancient buildings in the Pearl River delta area were selected as the samples,the test and data analysis were carried out accordance with the industry standard"The method of assessing the strength grade of clay brick by a test hammer",and the strength-rebound-curve of the old grey brick from ancient bildings in the Pearl River delta area was established,which provides a basis for the application of the rebound testing technology on the quality control in heritage conservation project.
出处 《科学技术与工程》 2011年第13期3111-3113,3118,共4页 Science Technology and Engineering
基金 华南理工大学亚热带建筑科学国家重点实验室开放基金项目(2008KB19)资助
关键词 回弹曲线 古建筑 旧青砖试验 珠江三角洲 strength-rebound-curve ancient buildings old grey brick test pearl river delta area