期刊文献+

让实验室测试值更贴近真实世界防护值——护听器的声衰减值评价方法讨论 被引量:5

Discussion on Assessment Method for Acoustic Attenuation Value in Guarding Listening
下载PDF
导出
摘要 本文介绍了护听器声衰减值的评价方法,对比了我国、ISO、欧洲EN、美国ANSI和澳大利亚新西兰AS/NZS标准中关于护听器声衰减值评价方法的差异。着重讨论在测试过程中,使用不同的受试者和护听器佩戴方式得出的检测数据与真实世界防护值的一致性情况。研究表明,使用"受试者自行佩戴"的方式测得的数据能更好地反映护听器在真实世界的防护性能。 This paper introduces the assessment method for acoustic attenuation value in guarding listening,and contrasts the difference in standards of our country,ISO,EN,ANSI and AS/NZS.It emphasizes the coherence between real protective value and testing data which is measured with different examinees in different adorn fashion.Research shows that measured data with wearing by oneself can reflect the real protective performance preferably.
作者 刘玉飞
机构地区 [
出处 《中国个体防护装备》 2011年第2期35-38,共4页 China Personal Protective Equipment
关键词 护听器 声衰减值 评价方法 标准 guarding listening acoustic attenuation value assessment method standards
  • 相关文献

参考文献13

  • 1Berger,E.H.and Kerivan,J.E.(1983)."Influence of Physiological Noise and the Occlusion Effect on the Measurement of Real-Ear Attenuation at Threshold,"J.Acoust.Soc.Am.74(1),81-94. 被引量:1
  • 2Whitham,E.M.and Martin,A.M.(1976)."A Review of Methods of Measurement of the Acoustic Attenuation of Hearing. 被引量:1
  • 3Martin,AM(1979)."Dependence ofAcoustic Attenuation of Hearing Protectors on Incident Sound Level,"Br.J.Ind.Med.36,1-14. 被引量:1
  • 4EN 352-4:2001,Hearing Protectors,Safety Requirements and Testing-Level dependent ear-muffs. 被引量:1
  • 5Berger,E.H.(1983)."Considerations Regarding the Laboratory Measurement ofHearingProtector Attenuation,"inProceedings of Inter -Noise 83,edited by R.Lawrence,Institute of Acoustics,Edinburgh,U.K.,379-382. 被引量:1
  • 6Berger,EH(1998).EARLog Series,#21.Aearo Company,Indpls.,IN. 被引量:1
  • 7Berger,EH(1992).EARLog Series,#2Q Aearo Company,Indp1s.,IN. 被引量:1
  • 8Berger,ER,Franks,J.R,andLindgren,F.(1994)."Field Attenuationof Hearing Protectors -AnInternational Comparison,With an Update on the NRR,"Am.Ind.Hyg.Conf.,Anaheim,CA,paper 70. 被引量:1
  • 9Michael,K(1999)."Measurement of Insert-Type Hearing Protector Attenuation on the End-user:A Practical Alternative to the NRR,"Spectrum 16(4),13-17. 被引量:1
  • 10Edwards,R.G.,Broderson,A.B.,Green,W.W.,and Lempert,B.L.(1982)."A Second Field Investigation of Noise Reduction Afforded by InsertType Hearing Protectors,"NIOSH,U.S.Dept.of HHS,Rept.No.210-81-3001,Cincinnati,OH. 被引量:1

同被引文献13

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...