摘要
在役泵站长期受到内、外因素影响,泵站的安全性态会受到一定程度的影响,故应对在役泵站进行安全性态分析研究,为更好地评价泵站的安全状态提供依据。结合江苏省临洪东站工程实例,从工程土建结构、机电设备及金属结构检测、工程安全复核计算等方面对该工程进行安全性态分析研究,对照《泵站技术管理规程》(SL255-2000)[1]和《泵站安全鉴定规程》SL316-2004[2]得出该工程为3类泵站。
For the pumping stations in service,their security has been influenced to a certain extent under the long-term effects of both internal and external factors.So it is very urgent to give an appraisal for their safety in time in order to provide the bases for better evaluating the safety.Here,combining with the engineering example of Linhong East Pumping Station in Jiangsu Province,its safety state is analyzed and researched from the following aspects such as the safety inspection of civil structures,mechanical and electrical equipments and metal structures,as well as the calculation on engineering security check and so on,and then,this project is confirmed as a third class pumping station by consulting the rules for technical management and safety appraisal of pumping stations.
出处
《水利与建筑工程学报》
2011年第2期139-143,共5页
Journal of Water Resources and Architectural Engineering
关键词
泵站
安全性态
安全检测
安全复核
有限元
pumping station
safety state
safety inspection
security check
finite element