可燃气体排放系统是石油化工设计中确保安全、防止火灾爆炸危险的重要安全措施之一。其中火炬总管的配管设计对整个排放系统影响较大,文中介绍了火炬总管排放的特点及火炬总管的应力分析与计算。
Flammable gas discharge system is one of measures for ensuring safety and preventing fire and explosion hazards. However, the piping design for flare head has relatively large effect to whole discharge system. In this article, the discharge feature of flare head was introduced, and the analysis of the stresses in flare head was performed.
出处
《化工设备与管道》
CAS
2011年第2期44-48,共5页
Process Equipment & Piping
关键词
火炬总管
管道布置
应力分析
计算
flare head piping
piping arrangement
stress analysis
calculation