摘要
介绍了灯泡贯流式水轮发电机组励磁系统的起励原理及方式,以广东省潮州供水枢纽电站运行过程中发生的励磁系统无法自动起励等故障为例、论述了故障分析的思路与处理方法。
An introduction was made on the field-flashing theory and modes of bulb turbine generator excitation system. Taking the automatic field-flashing failure occurred at Chaozhou Water Supply Complex of Guangdong Province as example, the author discussed the failure analysis route and treatment methods.
出处
《广西水利水电》
2011年第2期55-57,共3页
Guangxi Water Resources & Hydropower Engineering
关键词
灯泡贯流式
水轮发电机
励磁系统
起励方式
Bulb type
turbine generator
excitation system
field-flashing mode