摘要 室内步行街拟作为人员安全疏散的临时安全区,对其机械排烟系统设计进行探讨。对某大型商业综合体内的室内步行街进行研究,理论确定机械排烟系统的排烟量,然后利用FDS进行模拟验证,并提出合理的防烟分区划分。 In this paper,design of mechanical smoke exhaust system was studied,which was one of the essential conditions for indoor walking street to be used as the temporary safety zone for safety evacuation.The indoor walking streets of a large commercial complex were taken as an example.The empirical formula was used to identify the exhaust quantity of mechanical smoke exhaust system.Then,fire dynamics simulator was used to verify the calculated exhaust quantity,and a reasonable control method was proposed.
出处 《消防科学与技术》 CAS 北大核心 2011年第4期283-285,共3页 Fire Science and Technology
关键词 步行街 排烟系统 性能化设计 FDS atrium smoke exhaust performance-based design FDS
  • 相关文献

参考文献5

  • 1GB 50045-95(2005),高层民用建筑设计防火规范[S]. 被引量:24
  • 2NFPA92B-2002,烟气控制系统指南[S]. 被引量:9
  • 3ISOTC92-2009,消防安全工程-烟气层高度计算公式[S]. 被引量:1
  • 4公安部天津消防研究所.建筑物性能化防火设计技术导则[R].国家十五重点科技攻关项目专题四研究报告,2004. 被引量:8
  • 5国家消防工程技术研究中心.某商业广场消防安全性能化设计评估报告[R],2010. 被引量:1