期刊文献+

种植系统设计对保存种植体颈部骨组织的进展研究 被引量:1

下载PDF
导出
摘要 种植修复并行使功能后,常出现种植体颈部周围的骨吸收。颈部吸收后,可造成种植体冠根比例增大,种植体周围炎,最终导致种植体的早期失败。本文就近年来保存种植体颈部骨组织的一系列设计作一综述。
作者 王蓉 徐欣
出处 《中国口腔种植学杂志》 2010年第4期208-210,共3页 Chinese Journal of Oral Implantology
  • 相关文献

参考文献13

  • 1Lin S, Shi S, LeGerosRZ, et al. Three-dimensional finite element analyses of four designs of a high- strength silicon nitride implant, Implant Dent, 2000,9 (1) :53-60. 被引量:1
  • 2Holmgren EP, Seckinger R J, Kilgren LM, et al. Evaluating parameters of osseo integrated dental implants using finite clement analysisa two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol, 1998, 24 (2) : 80-88. 被引量:1
  • 3孔亮,刘宝林,胡开进,李德华,宋应亮,马攀,杨劲.螺纹种植体螺距的优化设计和应力分析[J].华西口腔医学杂志,2006,24(6):509-512. 被引量:23
  • 4Davies JE. Understanding peri-implant endosseous healing [J] . J Dent Educ, 2003, 67 (8) :932-949. 被引量:1
  • 5Puleo DA, Nanci A. Understanding and controlling the bone-implant interface [J] . Biomaterials, 1999, 20 (23/24) : 2311-2321. 被引量:1
  • 6Davies JE. Bone bonding at natural and biomaterial surfaces [ J] .Biomaterials, 2007,28 (34) : 5058-5067. 被引量:1
  • 7Chun H J, Shin HS, Han CH, et al. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis. Int J Oral Maxillofac Implants, 2006, 21 (2) : 195-202. 被引量:1
  • 8Lazzara R J, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels [J] .Int J Periodontics Restorative Dent, 2006, 26 (1) :9-17. 被引量:1
  • 9Broggini N, McManus LM, Hermann JS, et al. Persistent acute inflammation at the implant-abutment interface [J] . J Dent Res, 2003, 82 (3) : 232-237. 被引量:1
  • 10Gardner DM. Platform switching as a means to achieving implant esthetics N Y State Dent J,2005, 71 (3) :34-37. 被引量:1

二级参考文献13

  • 1Cehreli M,Duyck J,De Cooman M,et al.Implant design and interface force transfer.A photoelastic and strain-gauge analysis[J].Clin Oral Implants Res,2004,15(2):249-257. 被引量:1
  • 2Ivanoff C J,Grondahl K,Sennerby L,et al.Influence of variations in implant diameters:A 3-to 5-year retrospective clinical report[J].Int J Oral Maxillofac Implants,1999,14(2):173-180. 被引量:1
  • 3Brunski JB.Biomechanical considerations in dental implant design[J].Int J Oral Implantol,1988,5(1):31-34 被引量:1
  • 4Timoshenko SP,Goodier JN.Theory of elasticity[M].Singapore:McGraw-Hill International Book Co.,1984:15-40. 被引量:1
  • 5Zienkiewicz OC.The finite element method in engineering science[M].4th ed.New York:McGraw-Hill International Book Co.,1989:100-120. 被引量:1
  • 6Kitamura E,Stegaroiu R,Nomura S,et al.Biomechanical aspects of marginal bone resorption around osseointegrated implants:Considerations based on a three-dimensional finite element analysis[J].Clin Oral Implants Res,2004,15(4):401-412. 被引量:1
  • 7Cook SD,Klawitter JJ,Weinstein AM.A model for the implantbone interface characteristics of porous dental implants[J].J Dent Res,1982,61(8):1006-1009. 被引量:1
  • 8Borchers L,Reichart P.Three-dimensional stress distribution around a dental implant at different stages of interface development[J].J Dent Res,1983,62(2):155-159. 被引量:1
  • 9Colling EW.The physical metallurgy of titanium alloys[M].American Society for Metals,Ohio:Metals Park,1984:53-78. 被引量:1
  • 10Lewinstein I,Banks-Sills L,Eliasi R.Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis[J].Int J Oral Maxillofac Implants,1995,10 (3):355-366. 被引量:1

共引文献22

同被引文献17

  • 1孔亮,刘宝林,胡开进,李德华,宋应亮,马攀,杨劲.螺纹种植体螺距的优化设计和应力分析[J].华西口腔医学杂志,2006,24(6):509-512. 被引量:23
  • 2马攀,刘洪臣,李德华,林升,彭勤建,史真,吴晓霞.三种螺距对种植体初期稳定性影响的有限元研究[J].口腔颌面修复学杂志,2007,8(1):47-49. 被引量:20
  • 3Huang HL, Hsu JT, Fuh LJ, et al. Biomechanical simulation of various surface roughnesses and geometric designs on an immediately loaded dental implant [ J ] . Comput Biol Med, 2010, 40 ( 5 ) : 525-532. 被引量:1
  • 4Chang PK, Chen YC, Huang CC, et al. Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading : a finite element study [J]. Int J Oral Maxillofac Implants, 2012, 27 ( 6 ) : e96-101. 被引量:1
  • 5Huang HM, Lee SY, Yeh CY, et al. Resonance frequency assessment of dental implant stability with various bone qualities : a numerical approach [ J ] . Clin Oral Implants Res, 2002, 13 ( 1 ) : 65-74. 被引量:1
  • 6Mellal A, Wiskott HW, Botsis J, et al. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data [ J ] . Clin Oral Implants Res, 2004, 15 ( 2 ) : 239-248. 被引量:1
  • 7Hou SM, Hsu CC, Wang JL, et al. Mechanical tests and finite element models for bone holding power of tibial locking screws [J]. Clin Biomech ( Bristol, Avon ), 2004, 19 ( 7 ) : 738-745. 被引量:1
  • 8Tepper G, Haas R, Zechner W, et al. Three-dimensional finite element analysis of implant stability in the atrophic posterior maxilla : a mathematical study of the sinus floor augmentation [ J ] . Clin Oral Implants Res, 2002, 13 ( 6 ) : 657-665. 被引量:1
  • 9Cheng YC, Lin DH, Jiang CP. Application of uniform design to improve dental implant system [ J ] . Biomed Mater Eng, 2015, 26 ( Suppl 1 ) : S533-S539. 被引量:1
  • 10Orsini E, Giavaresi G, Trir ~ A, et al. Dental implant thread piteh and its influenee on the osseointegration proeess: an in vivo eomparison study [ J ]. Int J Oral Maxillofae Implants, 2012, 27 ( 2 ): 383-392. 被引量:1

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部