期刊文献+

偏瘫患者与正常人在五项日常生活活动中的表面肌电分析 被引量:9

Surface electromyographic analysis during five kinds of activities of daily living in normal subjects and hemiplegic patients
下载PDF
导出
摘要 目的:应用表面肌电描记术(sEMG)来研究偏瘫患者和正常人在日常生活活动(ADL)中的上肢相关肌肉表面肌电特点。方法:应用Megawin表面肌电系统来采集15例正常人(正常组)和10例偏瘫患者(偏瘫组)在执行抬臂、梳头、喝水、摸对侧肩、摸后口袋这5项ADL时的上肢相关肌肉表面肌电信号。经信号处理得到肱二头肌、肱三头肌、三角肌前部、三角肌中部、三角肌后部、前锯肌、背阔肌、斜方肌上部、斜方肌下部的均方根(RMS)比值,并分析正常组和偏瘫组上肢相关肌肉RMS比值异同。结果:偏瘫组较正常组肱三头肌、三角肌前部、三角肌中部、三角肌后部、前锯肌和斜方肌下部RMS比值显著增大(P<0.05)。结论:偏瘫患者可采用与正常人不同的肌肉收缩策略来完成ADL。 Objective:To study the surface electromyography (sEMG) features of normal subjects and hemiplegic patients in 5 kinds of activities of daily living (ADL). Method:Megawin sEMG system was used to record the sEMG data of 15 normal subjects(normal group) and 10 hemiparetic patients(hemiplegic group) during performing 5 kinds of ADLs. The tasks were reaching up, combing, drinking, touching lateral shoulder and touching back pocket. After managing, the root-mean-square (RMS) ratios of biceps brachii muscle, triceps brachii muscle, anterior part of deltoid muscle, median part of deltoid muscle, lateral part of deltoid muscle, serratus anterior muscle, latissimus dorsi muscle, upper part of trapezius muscle and lower part of trapezius muscle were obtained. And then, the RMS ratios in normal group and hemiplegic group were compared. Result: The RMS ratios of hemiplegic group increased significantly in triceps hrachii, anterior part of deltoid muscle, median part of deltoid muscle, laterior part of deltoid muscle, serratus anterior muscle and lower part of trapezius muscle(P〈0.05). Conclusion: The hemiplegic patients may utilize different from healthy subjects' muscle contraction strategies to perform ADL.
出处 《中国康复医学杂志》 CAS CSCD 北大核心 2011年第3期236-239,250,共5页 Chinese Journal of Rehabilitation Medicine
基金 国家"863"计划项目(2007AA04Z204) 国家自然科学基金项目(50775080) 国家科技部"十一五"支撑计划项目(2008BAI50B04)
关键词 偏瘫 上肢 日常生活活动 表面肌电描记术 hemiplegia upper extremity activities of daily living surface electromyography
  • 相关文献

参考文献21

  • 1Niehols-Larsen DS, Clark PC, Zeringue A, et al. Factors in- fluencing stroke survivors' quality of lif~ during subaeute re- covery[J]. Stroke,2005,36(7):1480-1484. 被引量:1
  • 2Merletti R, Parker P. Electromyography: physiology, engineer- ing, and noninvasive applications[M]. USA:John Wiley & Sons, Inc,2004. 被引量:1
  • 3Soderberg GL, Knutson LM. A guide for use and interpreta- tion of kinesiologie eleetromyographie data[J]. Phys Ther,2000, 80(5):485-498. 被引量:1
  • 4Simoneau GG, Marklin RW, Berman JE. Effect of computer keyboard slope on wrist position and forearm electrmnyography of typists without musculoskeletal disorders[J]. Phys Ther,2003, 83(9):816-830. 被引量:1
  • 5Soderberg GL, Cook TM, Rider SC, et al. Electromyographic activity of selected leg musculature in subjects with normal and chronically sprained ankles performing on a BAPS board [J]. Phys Ther,1991(71):514-522. 被引量:1
  • 6张文彤主编..世界优秀统计工具 SPSS 11统计分析教程 基础篇[M].北京:北京希望电子出版社,2002:302.
  • 7张文彤主编..世界优秀统计工具SPSS 11统计分析教程 高级篇[M].北京:北京希望电子出版社,2002:346.
  • 8郑荣强,王予彬,王惠芳.表面肌电在膝关节运动创伤康复中的应用[J].中国康复医学杂志,2008,23(1):81-83. 被引量:14
  • 9Yang JF, Winter DA. Electromyographie amplitude normaliza- tion methods: improving their sensitivity as diagnostic tools in gait analysis[J]. Arch Phys Med Rehabil,1984,65(9):517- 521. 被引量:1
  • 10Yang JF, Winter DA. Electromyography reliability in maxi- mal and submaximal isometric contractions[J]. Arch Phys Med Rehabil, 1983,64(9):417-420. 被引量:1

二级参考文献63

共引文献147

同被引文献137

引证文献9

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部