铁芯电抗器直流偏磁对PAPF滤波性能的影响研究 被引量:6

Effect of Iron-core Reactor DC Bias on Filtering Performance of PAPF
下载PDF
导出
摘要 实验发现,使用铁芯电抗器的三相四线制并联型有源电力滤波器(Parallel Active Power Filter,PAPF)投入后系统电流偶次谐波增幅明显,以2次谐波增幅最大。本文对此现象进行了详细的理论分析,并在MATLAB环境下进行了有无直流偏磁情况下的仿真。仿真和实验结果表明,铁芯电抗器直流偏磁是产生偶次谐波的主因,进而影响到PAPF的滤波性能。该结论对PAPF的实际工程应用设计具有一定的指导意义。 Through the experiments,it is found that when three-phase four-wire parallel active power filter(PAPF) using iron-core reactor is connected to power grid,even-order harmonic system current increases significantly,especially second-order harmonic increases largest.This phenomenon is expressed in detail by theoretical analysis and has been simulated under MATLAB environment,with or without DC bias.Simulation and experimental results show that iron-core reactor generating DC bias is the main cause of even-order harmonics and furthermore affects the PAPF filtering performance.Such a conclusion may be advantageously used in guiding in the engineering design of PAPF for the future.
出处 《电测与仪表》 北大核心 2011年第3期44-49,共6页 Electrical Measurement & Instrumentation
基金 国家自然科学基金资助项目(60874109)
关键词 有源滤波器 输出滤波器 偶次谐波 直流偏磁/铁芯电抗器 active power filter output filter even-order harmonic DC bias/iron-core reactor