摘要 目的为确保临床治疗的效果,对新鲜冰冻血浆经白细胞过滤后对凝血因子及血浆蛋白的影响进行研究。方法对白细胞过滤前后新鲜冰冻血浆凝血因子及血浆蛋白的活性进行测定。结果新鲜冰冻血浆白细胞过滤前后,PT、APTT、FIB、FⅤ:C、FⅧ:C都有明显改变(P<0.05),TP和ALB无改变(P>0.05)。结论白细胞过滤可使新鲜冰冻血浆凝血因子活性下降,但仍能保持在正常治疗水平之上,可以满足临床治疗的需要。 Objective To ensure the effectiveness of clinical treatment,to study the effects of fresh frozen plasma filtered by the white blood cells on plasma proteins and clotting factor.Methods Activity of coagulation factors of fresh frozen plasma and plasma proteins were measured respectively before and after filtration of the white blood cell.Results It had a significant change about PT、APTT、FIB、FⅤ:C、FⅧ:C of Fresh frozen plasma before and after leukocyte filtration(P0.05).It had not significant change about TP and ALB(P0.05).Conclusion Activity of Clotting factor of fresh frozen plasma decreased after leukocyte filtration,but it still remains above normal therapeutic levels,which can meet the need of clinical treatment.
出处 《哈尔滨医药》 2011年第1期15-15,共1页 Harbin Medical Journal
关键词 新鲜冰冻血浆 白细胞过滤器 血浆凝血因子 血浆蛋白 Fresh frozen plasma Leucocyte filter Plasma clotting factors Plasma protein
  • 相关文献

参考文献4

二级参考文献33

共引文献59

同被引文献62

  • 1杨江存,于青,李芒会,董选玲,宋耀军,任健康.白细胞过滤对新鲜冰冻血浆凝血因子及血浆蛋白的影响研究[J].临床检验杂志,2006,24(1):66-67. 被引量:4
  • 2中华人民共和国卫生部.中国输血技术操作规程(血站部分)[M].天津:科学技术出版社,1997,81-83. 被引量:15
  • 3田兆嵩.临床输血进展[M].成都:四川科学技术出版社,2010:178. 被引量:15
  • 4沈永生 任士军.利用分光光度的三种波长直接测定血清游离血红蛋白方法介绍[J].中华检验学杂志,1988,. 被引量:6
  • 5Serious Hazards of Transfusion (SHOT). Annual Report 2003. Manchester: Serious Hazards of Transfusion Steering Group,2003. 被引量:1
  • 6Kleinman S, Grossman B, Kopko P. A national survey of transfu- sion-related acute lung injury risk reduction policies for platelets and plasma in the United States. Transfusion,2010,50(6) :1312- 1321. 被引量:1
  • 7Vogler EA, Siedlecki CA. Contact activation of blood-plasma coag- ulation. Biomaterials, 2009,30 (10) : 1857 -1869. 被引量:1
  • 8Whelihan MF, Orfeo T, Gissel MT. Coagulation procofactor activa- tion by factor Xia. J Thromb Haemost,2010,8(7) :1532-1539. 被引量:1
  • 9Yazer MH, Cortese-Hassett A, Triulzi DJ. Coagulation factor levels in plasma frozen within 24 hours of phlebotomy over 5 days of stor- age at 1 to 60C. Transfusion ,2008,48 (12) :2525-2530. 被引量:1
  • 10国家食品药品监督管理局.一次性使用去白细胞滤器.YY0329-2009.2009-06.16. 被引量:1