期刊文献+

牙齿粘接强度的测定及其影响因素 被引量:8

Testing of dental bonding strength and its factors of influence
下载PDF
导出
摘要 牙齿粘接强度是表征粘接剂粘接效果的重要指标,体外测定牙齿粘接强度是常用的方法。本文介绍了体外测定牙齿拉伸粘接强度及剪切粘接强度技术要求、测定方法及影响测定结果的因素。
作者 赵信义
出处 《口腔材料器械杂志》 2010年第3期143-147,166,共6页 Chinese Journal of Dental Materials and Devices
  • 相关文献

参考文献23

  • 1ISO/TS 11405:2003 Dental materials-Testing of adhesion to tooth structure. 被引量:1
  • 2赵信义,何惠明,刘芳,王俊成.试样夹具对微拉伸黏结强度测定的影响[J].牙体牙髓牙周病学杂志,2007,17(1):20-24. 被引量:5
  • 3Driessen CH,Coetzee WJC.Advanced testing device to evaluate characteristics of dental materials:The Bencor Multi-T.Transactions for the Second International Congress on Dental Materials,1993;p.274:Abstract P~136. 被引量:1
  • 4Arao T,Nakahayashi N.Effect of miniaturized dumbbell-shaped specimen to identify bonding of resin to bovine dentin.J Jpn Dent Mater 1997;16:175~81. 被引量:1
  • 5Shono Y,Ogawa T,Terashita M,et al.Regional measurement of resin-dentin bending as an array.J Dent Res 1999;78(2):699~705. 被引量:1
  • 6Lopes GC,Baratieri CM,Baratieri LN,et al.Bonding to cervical sclerotic dentin:effect of acid etching time.J Adbes Dent 2004;6(1):19~23. 被引量:1
  • 7Sano H.Tensile bond strength vs.Surface area for dentin bonding.Jpn J Conserv 1994;34:882~887. 被引量:1
  • 8El Zohairy AA,de Gee AJ,de Jager N,et al.The influence of specimen attachment and dimension on microtensile strength.J Dent Res 2004;83(5):420~4. 被引量:1
  • 9Pashley DH,Sano H,Ciucchi B,et al.Adhesion testing of dentine bonding agents:a review.Dent Mater 1995;11:117~125. 被引量:1
  • 10Van Noort R,Howard IC,Cardew GE,et al.The effect of local interfacial geometry on the measurement of the tensile bond strength to dentin.J Dent Res 1991;70(5):889~93. 被引量:1

二级参考文献7

  • 1Pashley DH,Carvalho RM,Sano H,et al.The microtensile bond test:a review.J Adhes Dent,1999,1(4):299-309 被引量:1
  • 2Sano H,Shono T,Sonoda H,et al.Relationship between surface area for adhesion and tensile bond strength-evaluation of a microtensile bond test.Dent Mater,1994,10(4):236-240 被引量:1
  • 3Leloupl G,Hoore WD,Bouter D,et al.Meta-analytical review of factors involved in dentin adherence.J Dent Res 2001;80(7):1605-1614 被引量:1
  • 4Perdigao J,Geraldeli S,Carmo AR,et al.In vivo influence of residual moisture on moicrotensile bond strengths of one-bottle adhesive.J Esthet Restor Dent,2002,14(1):31-38 被引量:1
  • 5Ambrosano GMB,Cavalcanti AN,Soeiro CRM,et al.Variability in bond strength tests used in dentistry studies.J Dent Res,2005,84 (Spec Iss A):2965 被引量:1
  • 6El Zohairy AA,de Gee AJ,de Jager N,et al.The influence of specimen attachment and dimension on microtensile strength.J Dent Res,2004,83(5):420-424 被引量:1
  • 7Staninec M,Marshall GW,Hilton JF,et al.Ultimate tensile strength of dentin:evidence for a damage mechanics approach to dentin failure.J Biomed Mater Res (Appl Biomater),2002,63(3):342-345 被引量:1

共引文献4

同被引文献58

引证文献8

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部