摘要
制冷实验装置温度传感器的校准方法通常都存在着一定的系统误差,本文根据制冷实验装置的特点及系统误差产生的原因,重点阐述了温度传感器系统在线校准的方法,同时简要介绍了制冷实验室操作人员日常校准的方法。
The calibration methods on temperature transducer system of refrigerating experiment unit exists usually systematic error.According to the features about refrigerating experiment unit and the existence reasons about its systematic error,introduced in point the on-line calibration methods on temperature transducer system,and introduced the daily calibration method about refrigeration laboratory operators.
出处
《制冷空调与电力机械》
2011年第1期70-72,共3页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
制冷实验装置
温度传感器
在线校准
日常校准
refrigerating experimental unit
temperature transducer
on-line calibration
daily calibration