CT肾动脉造影:低剂量对比剂及变速注射方式的可行性研究 被引量:4

Feasibility of CT Angiography for the Renal Arteries with Low Dose Contrast Material in the Different Injection Condition
原文传递
导出
摘要 目的探讨在变速注射条件下64层螺旋CT肾动脉造影中使用低剂量对比剂的可行性。资料与方法对10名健康自愿者行腹主动脉(右侧膈顶水平层面)同层动态CT增强扫描,取得主动脉弓时间-密度曲线(time-density curve,TDC),得到触发扫描的理论阈值。将80例临床疑有肾动脉病变的患者按随机分类法分成两个使用不同对比剂注射方法组(A组、B组),每组40例,而后行64层螺旋CT肾动脉造影并记录每公斤体重对比剂用量。每组分别测量腹主动脉及双侧肾动脉CT值进行比较;所得图像按"优、良、差"3级进行评价。结果 B组对比剂用量较A组减少约0.51ml/kg体重,差异有显著统计学意义(Z=-8.231,P<0.01)。两组腹主动脉及双侧肾动脉CT值均>200HU,测量值差异无统计学意义(P>0.05)。肾动脉显像在两组病例中均能达到优或良,合计优良率均为100%(40/40),图像评分方面两组间差异无统计学意义(P>0.05)。结论在变速注射条件下64层螺旋CT肾动脉造影中,使用低剂量对比剂可以获得满意的肾动脉图像。 Objective To investigate the feasibility of 64-slice spiral CT angiography (CTA) with low dose CM for the renal arteries in the different injection condition.Materials and Methods Dynamic CT scan was performed at the same abdominal aorta level in 10 volunteers for measuring the CT value and the theoretical threshold was obtained by the time-density curve (TDC).CTA of the renal artery were performed on 80 patients suspected with renal artery lesions.80 patients were divided randomly into two groups(A and B,with 40 patients in each group)according to the inject method of CM,and then the dose of CM,CT attenuation values of the abdominal aortic artery (AAA) and bilateral renal arteries (RA) were measured for each group and the image quality was also recorded as excellent,good,and poor.Results The dose of group B was less than group A .CT attenuation values of both the AAA and RA were over 200 HU,and no significant difference between two groups was found.The image quality of renal arteries in two groups was well depicted as excellent or good and also was no significant difference.Conclusion It is feasible to use low dose CM in 64-slice spiral CTA for the renal arteries in the different injection condition.
出处 《临床放射学杂志》 CSCD 北大核心 2011年第2期215-218,共4页 Journal of Clinical Radiology
关键词 体层摄影术 X线计算机 血管造影术 肾动脉 Tomography X-ray computed Angiography Renal artery
  • 相关文献

参考文献10

  • 1周福德,王海燕.肾动脉狭窄的无创性检查研究进展[J].中华肾脏病杂志,2002,18(4):306-309. 被引量:14
  • 2Wong GT, Irwin MG. Contrast-induced nephropathy. Br J Anaesth, 2007.99:474. 被引量:1
  • 3张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69
  • 4Schweiger MJ, Chambers CE, Davidson CJ, et at. Prevention of contrast induced nephropathy:recommendations for the high risk patient undergoing cardiovascular procedures. Catheter Cardiovasc Interv, 2007,69 : 135. 被引量:1
  • 5Takamura Y,Tanooka A, Morimoto S, et al. Usefulness of three-dimensional CT angiography with a single bolus injection of contrast material for the examination of intracranial and cervical arteries in cerebrovascular disease screening. No Shinkei Geka,2001,29 :401. 被引量:1
  • 6Loutrianakis E, Stella D, hussain A, et al. Randomized comparison of fenaldopam and nacetylcysteine to saline in the prevention of radiocontrast nephropathy. J AM Coll Card,2003,41:327. 被引量:1
  • 7Trivedi HS, Moore H, Nasr S, et al. A randomized prospective trial to assess the role of saline hydration on the development of contrast nephrotoxicity. Nephron Clin Pract,2003 ,93 :29. 被引量:1
  • 8Call J, Sacrinty M, Applegate R, et al. Automated contrast injection in contemporary practice during cardiac catheterization and PCI: effects on contrast-induced nephropathy. Invasive Cardiol, 2006,18 : 469. 被引量:1
  • 9Davidson C, Stacul F, McCullough PA, et al. CIN Consensus Working Panel. Contrast medium use. Am J Cardiol,2006,98:42. 被引量:1
  • 10张雷,张追阳,吴文娟,王东,高煜,施谦,华冬英.64层螺旋CT肾动脉造影中使用低剂量对比剂的可行性研究[J].临床放射学杂志,2009,28(9):1287-1289. 被引量:4

二级参考文献35

  • 1李建初,张缙熙,周墨宽,程玉芳,姜玉新.彩色多普勒超声对肾动脉狭窄的评价[J].中华超声影像学杂志,1996,5(4):159-161. 被引量:30
  • 2Pannu HK, Fishnm EK. Muhidetector computed tomographic evaluation of the renal artery. Abdom imaging,2002,27:611. 被引量:1
  • 3Persson PB ,Tepel M. Contrast medium-induced nephropathy :the pathophysiology (Review). Kidney Int Suppl,2006,69 :8. 被引量:1
  • 4Wong GT, Irwin MG. Contrast-induced nephropathy. Br J Anaesth, 2007,99:474. 被引量:1
  • 5Al-Ghonaim M, Pannu N. Prevention and treatment of contrast-induced nephropathy. Tech Vase Interv Radiol,2006,9:42. 被引量:1
  • 6Katzberg RW,Haller C. Contrast-induced nephrotoxicity:clinical landscape (Review). Kidney Int Suppl,2006 ,69 :3. 被引量:1
  • 7Gleeson TG, Bulugahapitiya S. Contrast-induced nephropathy ( Review). AJR ,2004,183 : 1673. 被引量:1
  • 8Foley WD, Karcaaltincaba M. Compuled tomography angiography :principies and clinical applications. JCAT,2003,1:23. 被引量:1
  • 9Brink JA. Contrast optimization and scan timing for single and multidetector-row computed tomography. JCTA ,2003,1:3. 被引量:1
  • 10张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69

共引文献84

同被引文献56

  • 1孙培钰(综述),朱建华(审校).造影剂肾病的危险因素及防治进展[J].国际泌尿系统杂志,2007,27(4):559-562. 被引量:5
  • 2孙丛,柳澄,王道平,黄杰,王立君.多层螺旋CT低剂量高浓度对比剂腹部血管成像应用研究[J].放射学实践,2007,22(3):259-261. 被引量:18
  • 3Schweiger MJ,Chambers CE,Davidson CJ,et al.Prevention of con-trast induced nephropathy:recommendations for the high risk pa-tient undergoing cardiovascular procedures [J].Catheter CardiovascInterv,2007,69(1):135-140. 被引量:1
  • 4Weisbord SD,Palevsky PM.Radiocontrast,induced acute renal fail-ure [J].J Intensive Care Med,2005,20(2):63-75. 被引量:1
  • 5Wong GT,Irwin MG.Contrast-induced nephropathy [J].Br J An-aesth,2007,99(4):474-483. 被引量:1
  • 6Call J,Sacrinty M,Applegate R,et al.Automated contrast injectionin contemporary practice during cardiac catheterization and PCI:ef-fects on contrast-induced nephropathy [J].J Invasive Cardiol,2006,18(10):469-474. 被引量:1
  • 7Davidson C,Stacul F,Mc Cullough PA,et al.Contrast medium use[J].Am J Cardiol,2006,98(6A):42-58. 被引量:1
  • 8Yamashita Y,Komohara Y,Takahashi M,et al.Abdominal helicalCT:evaluation of optimal doses of intravenous contrast material-aprospective randomized study [J].Radiology,2000,216(3):718-723. 被引量:1
  • 9Ho LM,Nelson RC,Delong DM.Determining contrast mediumdose and rate on basis of lean body weight:does this strategy im-prove patient-to-patient uniformity of hepatic enhancement duringmulti-detector row CT? [J].Radiology,2007,243(2):431-437. 被引量:1
  • 10Itoh S,Fukushima H,Takada A,et al.Assessment of anomalous pan-creaticobiliary ductal junction with high-resolution multiplanar re-formatted images in MDCT [J].AJR Am J Roentgenol,2006,187(3):668-675. 被引量:1

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部