摘要 目的:探讨CT 机的性能检测方法。材料和方法:CT 设备20 台。性能检测参数为层厚、CT 值线性与对比度标度、均匀性、噪声、空间分辨力、密度分辨力、诊视床定位光精度、诊视床运动精度、剂量指数( CTDI) 等九项。用Catphan体模以及RADCAL 剂量测试设备对CT 机进行性能参数检测。用近2 个月多部位照片进行临床照片评估。结果:9 台CT 机全部参数合格,其中有3 台照片质量评估为1 等,6 台照片质量评估为2 等,7 台CT 机有1 项参数不合格,照片质量评估为2 等,4 台CT 机有3 项以上参数不合格,照片质量评估为2 等。结论:该检测方法可对CT 机的各项参数作精确的检测,能够满足CT 机质量保证性能检测的要求。 Purpose:To develop the methods of performance testing for computed tomography (CT).Materials and methods:20 sets of CT,The measured parformance parameters of CT are slice width,linearity of CT value,uniformity,noise,spatal resolution,low contrast resolution,precision of patient alignment system,scan incrementation and index of CT dose (CTDI).The Catphan phantom and the Radcal dosemeter were used to measure the performance parameters.The patient images which were obtained in recent two months were arbitrarily taken out for evaluation.Results:In 9 sets of CT all the parameters were up to the standards and the quality of images in 3 sets of CT was in first grade ,the quality of image in 6 sets of CT was in second grade:in 7sets of CT only one parameter was not up to the standards and the quality of image in these CT equipments was in second grade;in 4 sets of CT more than 3 performance parameters were not up to the standards and the quality of images in these CT equipments was in second grade.Conclusion:The methods of performance testing for CT work well,and are satisfied for the performance evaluation of CT.
出处 《中国医学影像学杂志》 CSCD 1999年第3期220-224,共5页 Chinese Journal of Medical Imaging
关键词 性能检测 CT 质量保证 体模 Quality assurance CT phantom performance testing
  • 相关文献

参考文献3

  • 1卫生部文件,卫计发[1996] 第216 号,1996年 被引量:1
  • 2卫生部文件,卫计发[1996] 第61 号,1996年 被引量:1
  • 3中华人民共和国卫生部,大型医用设备配置与应用管理暂行办法,1995年 被引量:1

同被引文献3

  • 11,Pei-Jan Paul Lin,Thomas J.Beck.Specification AndAcceptance Testing Of Computed Tomography Scanners[J].AAPM REPORT,No.39. 被引量:1
  • 23,Junji,Kazuyoshi,Yasuto O.Measurement of CT Section Thickness by Using the PartialVolume Effect[J].Radiology.1992,184∶870-872. 被引量:1
  • 3吴毅 杜国生 田中青.CT性能检测体模及检测方法[J].世界医疗器械,1999,6(4):58-62. 被引量:1