纤维支气管镜判断三种方法联合应用于双腔支气管导管就位的准确率 被引量:6

Positioning of double lumen endobronchial tube by three combined ethods with fibroptic bronchoscope
下载PDF
导出
摘要 目的以纤维支气管镜(FOB)判断联合应用听诊法、气道压力变化法及PETCO2波形法在双腔支气管导管(DLT)就位的准确率。方法选择胸科麻醉手术患者60例,静脉诱导后插入RobertshawDLT。通过三种方法联合应用调整导管位置达到标准后用FOB判断RobertshawDLT就位的准确率。结果平卧位时,DLT就位满意率为95%;侧卧位后,DLT就位满意率为93.4%。结论三种方法联合应用明显提高DLT就位满意率,但FOB仍是确定DLT位置的金标准。 Objective To observe the correctly positioning rate of left-sided double lumen endobronchial tube by combined adjustment of auscultation,PETCO2 and airway pressure changes.Methods Sixty adult patients undergoing thoracic surgery were intubated with Robertshaw DLTs. DLT position is checked and adjusted by fiberoptic bronchoscope(FOB). Results In the supine position,successful intubation is 57 cases by three combined methods,one of cases is shallower,two of cases are deeper,satisfactory rate is 95 percents;In the lateral decubitus position,successful intobution is 56 cases by three combined methods,two of cases is shallower,two of cases are deeper,satisfactory rate is 93.4 percents.Conclusion Three combined methods that are simple,reliable can be used repeatedly during postural changes without increasing the opportunities for injury,it is clinically a very good approach,but the absolute scope of safety is very small,FOB is necessary for positioning.
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2010年第12期1059-1060,共2页 Journal of Clinical Anesthesiology
基金 河北省科技计划资助项目(10276105D-5)
关键词 听诊 PETCO2 吸气峰压 双腔支气管导管 纤维支气管镜 Auscultation PETCO2 Inspiratory peak airway pressure Double lumen endobronchial tube Fiberoptic bronchoscope.
  • 相关文献

参考文献9

  • 1关健强,黑子清,马武华,孙海云,罗刚健.纤维支气管镜辅助右双腔气管导管插管[J].中国内镜杂志,2004,10(12):17-18. 被引量:28
  • 2陈秉学等主编..胸科肿瘤麻醉学[M].郑州:郑州大学出版社,2001:420.
  • 3欧阳葆怡,温晓晖,梁丽霞.双腔支气管导管型号选择分析[J].中华麻醉学杂志,2001,21(6):366-367. 被引量:68
  • 4Hurfor WE, Alfille PH, Bailin MT, et al. Placementand complication of double-lumen endotracheal tubes. Anesth Analg, 1992,74:14. 被引量:1
  • 5Hurford WE,Alfille PH. A quality improvement study of the placement and complications of double-lumen endobronchial tubes. J Cardiothorac Anesth, 1993,7: 517. 被引量:1
  • 6Klein U,Karzai W,Bloos F,et al. A role of fibreoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia. Anesthesiology, 1998,88 : 364-350. 被引量:1
  • 7Aziz HF, Martin JB, Moore JJ. The pediatiric disposable end tidal carbon dioxide deco role in endotracheal intubation in newborns. Perinatol, 1999,19 : 110-113. 被引量:1
  • 8ShowMY,Gob MH,Ti LK,et al. Predicting the depth of insertion of left-sided double-lumen endobronchial-tubes. Cardiothorac Vasc Anesth, 2002,16 : 456-458. 被引量:1
  • 9欧阳葆怡,梁丽霞,叶靖.左双腔支气管导管管端位置与吸气峰压变化的关系[J].临床麻醉学杂志,2004,20(6):349-352. 被引量:19

二级参考文献19

  • 1Smith GB,Hirsch NP,Ehrenwerth L.Placement of double lumen endobronchial tubes.Correlation between clinical impressions and bronchoscopic findings.Br J Anaesth,1986,58:1317-1320. 被引量:1
  • 2Alliaume B,Coddens J,Deloof T.Reliability of auscultation in positioning of double-lumen endobronchial tubes.Can J Anaesth,1992,39:687-690. 被引量:1
  • 3Slinger P.New trends in anesthesia for thoracic surgery including thoracoscopy.Can J Anaesth,1995,42:R77-84. 被引量:1
  • 4Szegedi LL,Bardoczky GI,Engelman EE,et al.Airway pressure changes during one-lung ventilation.Anesth Analg, 1997,84:1034-1037. 被引量:1
  • 5Ovassapian A. Flexible bronchoscopic positioning of right-sided double-lumen endobronchial tubes.J Bronchol, 1995,2:12-19. 被引量:1
  • 6Simon BA,Hurford WE,Alfille PH,et al.An aid in the diagnosis of malpositioned double-lumen tubes.Anesthesiology,1992,76:862-863. 被引量:1
  • 7Bardoczky GI,Levarlet M,Engelman E,et al.Continuous spirometry for detection of double-lumen endobronchial tube displacement.Br J Anaesth,1993,70:499-502. 被引量:1
  • 8Smith GB, Hirsch NP. Ehrenwerth J: placement of double-lumen endobronchial tubes. Correlation between clinical impressions and bronchoscopic findings[J]. Br J Anaesth, 1986, 58: 1317-1320. 被引量:1
  • 9Klein U, Karzai W, Blcos F, et al. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study[J]. Anesthesiology, 1998,88:346-350. 被引量:1
  • 10Burk WJ. Should a fiberoptic bronchoscope be routine used to position a double-lumen tube?[J] [letter] Anesthesiology, 1988, 68: 826. 被引量:1

共引文献105

同被引文献35

引证文献6

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部