摘要 2005年12月14日,因设计、施工不当,仪器方面的失误和人为失误等众多原因,美国Taum Sauk抽水蓄能电站上水库失事,自此停止运营。主要介绍失事的过程和原因,供参考。 A variety of design and construction flaws,instrumentation error,and human errors contributed to a catastrophic failure of the upper reservoir on Dec 14,2005.Ever since,the project has been out of operation.This paper introduced the failure process and cause reasons were analysed,for reference.
作者 崔弘毅
出处 《大坝与安全》 2010年第5期61-66,共6页 Dam & Safety
关键词 TAUM Sauk抽水蓄能电站 失事 过程 原因 Taum Sauk pumped storage project failure process reason
  • 相关文献

参考文献3

  • 1J.David Rogers,Conor M.Watkins.Overview Of The Taum Sauk Pumped Storage Power Plant Upper Reservoir Failure,Reynolds County,MO[C].6th International Conference on Case Histories in Geotechnical Engineering,Arlington,2008. 被引量:1
  • 2FERC Taum Sauk Investigation Team.Report of Findings on the Overtopping and Embankment Breach of the Upper Dam-Taum Sauk Pumped Storage Project,FERC No.2277[R].2006. 被引量:1
  • 3FERC Independent Panel of Consultants(IPOC).Taum Sauk Upper Dam Breach FERC No.P-2277,Technical Reasons for the Breach of December 14,2005[R].2006. 被引量:1