摘要
介绍ISO10605:2008新版标准中人体ESD模型的分类及表征特性;与2001版相比,新版标准增加了150pF/330Ω和330pF/330Ω两种放电模块。同时,介绍了新版标准中接触法校准静电枪的内容和最新的勘误单。最后讨论了静电枪的接地方式,指出静电枪的接地线与水平耦合平面直接相连的情况并不能达到考核受试设备的效果。
This article introduces the ISO 10605:2008 and its application of the updating human ESD model, discharge modes and the selection of discharge network. The differences between ISO 10605:2008 and ISO 10605:2001 are discussed; two discharging modules, 150 pF/330 Ω and 330 pF/330 Ω are introduced in the new version. And ISO 10605:2008 technical corrigendum 1 is also introduced. Finally, the different methods of grounding are discussed; it is found that the situation when bonding the grounding cable of ESD gun to horizontal coupling plane cannot reach the desired effect to examine the device under test.